Characters shall be selected from fonts where the width of the uppercase letter “O” is 60 percent minimum and 110 percent maximum of the height of the uppercase letter “I”....
Search Results "Minimum Dimension"
-
11B-703.2.4 Character proportions
-
11B-703.5.4 Character proportions
Characters shall be selected from fonts where the width of the uppercase letter “O” is 60 percent minimum and 110 percent maximum of the height of the uppercase letter “I”....
-
5.4.1 Transfer Support Location for M301 and M302
This would be a minimum requirement....
-
5.4.3 Transfer Support Height for M301 and M302
The purpose of a minimum height is to ensure that the gripping surface is at an adequate height to facilitate positioning during a transfer....
-
§35.150(d)(3)
(3) The plan shall, at a minimum --...
-
§ 35.150(d)(3)
(3) The plan shall, at a minimum—...
-
5.8.3.1 Breast Platform Height Recommendations
The final version of the criteria must clarify that the specified height range is a minimum range of travel....
- Willoughby Industries UW-1317-HEU-FA Series Contoured High Efficiency Urinal
- Cavity Sliders CL100 ADA LaviLock Hardware Set with 'Vacant / In Use' Indicator
- Allegion LCN 5010 Series Overhead Concealed Door Control
- Lift-U® Fold-Out Rising Floor Ramp
-
19 Inch Low Height
The highest and lowest points of the transfer surface on such equipment would have to be within the specified dimensions.”8 The Access Board proposed that the measurement should be taken...
-
(3) Adjustability: Transfer Surface Intermediate Heights
low transfer height and a minimum high transfer height....
-
1014.2.1.1 Clear Ground Space
The clear ground space shall be 36 inches (915 mm) minimum by 48 inches (1220 mm) minimum and shall be positioned for a parallel approach to the camp shelter. ...
-
Passing Spaces (R302.4) (Section-by-Section Analysis)
Passing spaces must be 1.5 meters (5 feet) minimum by 1.5 meters (5 feet) minimum. Passing spaces are permitted to overlap pedestrian access routes....
-
§ 36.602 General rule.
On the application of a State or local government, the Assistant Attorney General may certify that a code meets or exceeds the minimum requirements of the Act for the accessibility and usability...
-
9.5.2(2)(c)
(c) at least one toilet room for each gender or one unisex toilet room shall have a minimum clear door width of 32 in (815 mm), minimum turning space complying with 4.2.3, one water closet...
-
1014.2.1.1 Clear Ground Space
The clear ground space shall be 36 inches (915 mm) minimum by 48 inches (1220 mm) minimum and shall be positioned for a parallel approach to the camp shelter....
-
11B-1009.4.1 Clear deck space
A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
11B-703.5.4 Character proportions
Characters shall be selected from fonts where the width of the uppercase letter “O” is 60 percent minimum and 110 percent maximum of the height of the uppercase letter “I”....
-
11B-703.2.4 Character proportions
Characters shall be selected from fonts where the width of the uppercase letter “O” is 60 percent minimum and 110 percent maximum of the height of the uppercase letter “I”....
-
§ 38.153(c)(1)
(1) Doors shall have a minimum clear width when open of 30 inches (760 mm), measured from the lowest step to a height of at least 48 inches (1220 mm), from which point they may taper to...
-
11B-1009.2.3 Clear deck space
The space shall be 36 inches (914 mm) wide minimum and shall extend forward 48 inches (1219 mm) minimum from a line located 12 inches (305 mm) behind the rear edge of the seat....
-
11B-1009.2.3 Clear deck space
The space shall be 36 inches (914 mm) wide minimum and shall extend forward 48 inches (1219 mm) minimum from a line located 12 inches (305 mm) behind the rear edge of the seat....