Lavatories without base cabinets shall be installed with the centerline 18 inches (457 mm) minimum from an adjoining wall or fixture to allow for forward approach....
Search Results "Minimum Dimension"
-
11B-809.10.8.1 Location
-
11B-1007.2 Accessible routes
Where accessible routes intersect playing surfaces of holes, a 1 inch (25 mm) maximum curb shall be permitted for a width of 32 inches (813 mm) minimum. 3. ...
-
11B-1007.2 Accessible routes
Where accessible routes intersect playing surfaces of holes, a 1 inch (25 mm) maximum curb shall be permitted for a width of 32 inches (813 mm) minimum. 3....
-
11B-904.4.1 Parallel approach
A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum above the finish floor shall be provided....
-
11B-502.5 Vertical clearance
Parking spaces, access aisles and vehicular routes serving them shall provide a vertical clearance of 98 inches (2489 mm) minimum. [2010 ADA Standards] 502.5 Vertical Clearance....
-
11B-406.5.10 Diagonal curb ramps
Diagonal curb ramps with flared sides shall have a segment of curb 24 inches (610 mm) long minimum located on each side of the curb ramp and within the marked crossing....
-
Q2.) What are the types of “field conditions” that were anticipated where the advisory says “tolerances recognized by this provision include those for field conditions”?
Those are usually the dimensions that can safely be considered industry tolerances. ...
-
3.3.5 Seat Height
3.3.5 Seat Height Height dimension standards for seats prescribed in the Australian, Canadian and U.S. standards were very similar (480 mm or 18.9 in., 480 mm or 18.9 in. and 485 mm...
-
Suggested accessibility guidelines for exterior concrete surfaces
However, the ACI standards do not permit interpolation or extrapolation for dimension greater than or less than 10 feet....
-
Areas for further work
Measurement instruments Accuracy of instruments/measurement uncertainty Use of significant figures Metric conversions or dual unit standards Measurement of dimensions...
-
2004 ADA and ABA Accessibility Guidelines
The Access Board is also considering additional technical criteria based on the 2004 ADA and ABA Accessibility Guidelines for cross section dimensions and clearances around gripping surfaces...
-
3.3.3. Captioning Device Scoping Requirements
The Joint Comment suggested that movie theaters maintain a minimum number of captioning devices based on the number of auditoriums displaying digital movies within a movie theater, or by...
-
M303.2.4 Equipment Clearances (Section-by-Section Analysis)
The MDE NPRM preamble sought input with question 34 on whether the dimensions recommended by the Wheeled Mobility Anthropometry Project should be adopted.10 Three commenters responded....
-
The Target Population
For many dimensions women represent the smaller end of the distribution....
- BEA Inc. High/Low Mount Boxes Bronze Bollards
- KirbyBuilt Providence Picnic Table with Maximum Seating
-
4.1.7(3) Historic Preservation
(3) Historic Preservation: Minimum Requirements:...
-
Standing Supports (M304.3 and M305.3)
for single ramp scale and 40” minimum for dual ramp scale....
-
703.2.5 Character Height
Character height measured vertically from the baseline of the character shall be 5/8 inch (16 mm) minimum and 2 inches (51 mm) maximum based on the height of the uppercase letter "I"....
-
1015.2 Clear Ground Space
The clear ground space shall be 36 inches (915 mm) minimum by 48 inches (1220 mm) minimum and shall be positioned for either a forward or parallel approach to the viewing location. ...
-
Clear Deck Space
Clear Deck Space The base of the transfer platform must have a clear deck space adjacent to it that is 60 by 60 inches minimum, with a slope not steeper than 1:48 so a person using a...
-
703.2.5 Character Height
Character height measured vertically from the baseline of the character shall be 5/8 inch (16 mm) minimum and 2 inches (51 mm) maximum based on the height of the uppercase letter "I"....
-
4.2.4.1 Size and Approach
The minimum clear floor or ground space required to accommodate a single, stationary wheelchair and occupant is 30 in by 48 in (760 mm by 1220 mm) (see Fig. 4(a))....
-
1015.2 Clear Ground Space
The clear ground space shall be 36 inches (915 mm) minimum by 48 inches (1220 mm) minimum and shall be positioned for either a forward or parallel approach to the viewing location....