The signal-to-noise ratio for internally generated noise in assistive listening systems shall be 18 dB minimum....
Search Results "Minimum Dimension"
Commonly Searched Documents
-
11B-706.5 Signal-to-noise ratio
-
Mirrors: ADA Standard Section 603.3
Section 603.3 covers the current ADA Standards for mirrors in toilet and bathing rooms.
-
Unobstructed: ADA Standard Section 308.3.1
Section 308.3.1 covers the current ADA Standards for unobstructed side reach.
-
11B-603.3 Mirrors
In order for mirrors to be usable by people who are ambulatory and people who use wheelchairs, the top edge of mirrors should be 74 inches (1880 mm) minimum from the floor or ground. ◼...
-
11B-812.7.2 Marking
Access aisle markings may extend beyond the minimum required length....
-
11B-224.4 Guest rooms with communication features
TABLE 11B-224.4 GUEST ROOMS WITH COMMUNICATION FEATURES TOTAL NUMBER OF GUEST ROOMS PROVIDED MINIMUM NUMBER OF REQUIRED GUEST ROOMS WITH COMMUNICATION FEATURES...
-
11B-303.3 Beveled
Changes in level between ¼ inch (6.4 mm) high minimum and ½ inch (12.7 mm) high maximum shall be beveled with a slope not steeper than 1:2. Advisory 11B-303.3 Beveled....
- BORA Classic Cooktop Extraction System
- American Standard Home Cadet Bidet 5023.100
- Rath Microtech Line Powered Elevator Emergency Phone 2400-808DO
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
11B-802.1.2 Width
A single wheelchair space shall be 36 inches (914 mm) wide minimum. ...
-
1009.2.9 Lifting Capacity
Single person pool lifts shall have a weight capacity of 300 pounds. (136 kg) minimum and be capable of sustaining a static load of at least one and a half times the rated load....
-
Handrails
Handrails Pool stairs must have handrails with a minimum width between the rails of 20 inches and a maximum of 24 inches....
-
1009.2.9 Lifting Capacity
Single person pool lifts shall have a weight capacity of 300 pounds. (136 kg) minimum and be capable of sustaining a static load of at least one and a half times the rated load....
-
T503.5 Exterior Illumination for Boarding and Alighting Areas
Where doorways have steps, the illumination shall be 1 foot-candle (11 lux) minimum for a distance of 3 feet (915 mm) measured beyond the outside edge of the doorway or bottom step tread...
-
407.2.2.2 Visible Signals
Visible signal fixtures shall be centered at 72 inches (1830 mm) minimum above the finish floor or ground....
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
D6. Vestibule Clear Floor Space
Minimum alcove depth of 48 inches if both doors open out Minimum alcove depth of 48 inches + door width when door swings into alcove...
-
2.3.1 Standards
When the NYS standards were drafted in l988‒89, the manufacturers could not reach a consensus regarding minimum energy level of the IR light at a set distance from the emitters....
-
Prohibited Reduction in Access
Reductions in access are allowed only where, and to the extent that, the minimum level required in new construction is exceeded....
-
11B-602.9 Pedestrian protection
The protected area within which a drinking fountain is located shall be 32 inches (813 mm) wide minimum and 18 inches (457 mm) deep minimum, and shall comply with Section 11B-305.7....
-
IV.B.2.
Characters on signs required by paragraph IV.B.1 of this appendix shall have a width-to-height ratio between 3:5 and 1:1 and a stroke width-to-height ratio between 1:5 and 1:10, with a minimum...
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface, except...