ETA Editor's Note Sections from California Building Code Chapter 9 that are not adopted by Division of the State Architect - Access Compliance (DSA-AC) have been omitted....
Search Results "Assurances from Contractors"
Commonly Searched Documents
-
CHAPTER 9 FIRE PROTECTION SYSTEMS
-
CHAPTER 31 SPECIAL CONSTRUCTION
ETA Editor's Note This Guide contains only the excerpts from California Building Code Chapter 31 that are adopted by Division of the State Architect - Access Compliance (DSA-AC)....
-
CHAPTER 33 SAFEGUARDS DURING CONSTRUCTION
ETA Editor's Note This Guide contains only the excerpts from California Building Code Chapter 33 that are adopted by Division of the State Architect - Access Compliance (DSA-AC)....
-
CHAPTER 31B PUBLIC POOLS
ETA Editor's Note This Guide contains only the excerpts from California Building Code Chapter 31B that are adopted by Division of the State Architect - Access Compliance (DSA-AC)....
-
CHAPTER 16 STRUCTURAL DESIGN
ETA Editor's Note This Guide contains only the excerpts from California Building Code Chapter 16 that are adopted by Division of the State Architect - Access Compliance (DSA-AC)....
-
11B-703.5.4 Character proportions
Characters shall be selected from fonts where the width of the uppercase letter “O” is 60 percent minimum and 110 percent maximum of the height of the uppercase letter “I”....
-
CHAPTER 2 DEFINITIONS
ETA Editor's Note Sections from California Building Code Chapter 2 that are not adopted by Division of the State Architect - Access Compliance (DSA-AC) have been omitted....
-
CHAPTER 1 SCOPE AND ADMINISTRATION
ETA Editor's Note This Guide contains only the excerpts from California Building Code Chapter 1 that are adopted by Division of the State Architect - Access Compliance (DSA-AC)....
-
CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
ETA Editor's Note Sections from California Building Code Chapter 4 that are not adopted by Division of the State Architect - Access Compliance (DSA-AC) have been omitted....
-
CHAPTER 16A STRUCTURAL DESIGN
ETA Editor's Note This Guide contains only the excerpts from California Building Code Chapter 16A that are adopted by Division of the State Architect - Access Compliance (DSA-AC)....
-
CHAPTER 30 ELEVATORS AND CONVEYING SYSTEMS
ETA Editor's Note This Guide contains only the excerpts from California Building Code Chapter 30 that are adopted by Division of the State Architect - Access Compliance (DSA-AC)....
-
11B-604.8.1.2 Doors
Where located in the front partition, the door opening shall be 4 inches (102 mm) maximum from the side wall or partition farthest from the water closet....
-
Features of the ETA Standard Barrier Survey/Barrier Management System [Title II]
When possible, the barriers are all located on a floor or site plan to make sure the contractor who does the work can efficiently locate the problem in the field....
-
Verification of Service Animals
You must accept the following as evidence that the animal is indeed a service animal: the credible verbal assurances of a passenger with a disability using the animal, the...
-
Meeting Purpose
Note that whenever possible people should NOT be separated from assistance devices (cane, wheelchair, etc.)...
-
Factors to Consider in Planning For & Administering an ADA Facilities Compliance Plan
Your initial compliance efforts and your long-term success in integrating ADA requirements into your work will all benefit from early consideration of the following: First, consider your...
-
III.
Bass, 404 U.S. 336, 349 (1971) ("the requirement of a clear statement assures that the legislature has in fact faced, and intended to bring into issue, the critical matters involved in the...
-
11B-903.4 Back support
Back support shall be 48 inches (1219 mm) long minimum and shall extend from a point 2 inches (51 mm) maximum above the seat surface to a point 18 inches (457 mm) minimum above the seat...
-
DEFINITIONS
The term “AFAC Personnel” means any person working for AFAC, whether as an officer, agent, employee, volunteer, or independent contractor, including, without limitation, nurses, doctors,...
-
Introduction
This publication describes those problems so that owners, franchisors, architects, and building contractors can avoid these common ADA mistakes and comply with the law when designing and...
-
Back Wall: ADA Standard Section 607.4.1.1
Section 607.4.1.1 covers the current ADA Standards for back wall grab bars in bathtubs with permanent seats.
-
11B-809.10.6.5 Thresholds
Where provided thresholds shall be 2 inches (51 mm) maximum in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from the horizontal...
-
11B-809.10.8.1 Location
Lavatories without base cabinets shall be installed with the centerline 18 inches (457 mm) minimum from an adjoining wall or fixture to allow for forward approach....
-
11B-607.4.1.1 Back wall
Each grab bar shall be installed 15 inches (381 mm) maximum from the head end wall and 12 inches (305 mm) maximum from the control end wall....