ETA Editor's Note Sections from California Building Code Chapter 4 that are not adopted by Division of the State Architect - Access Compliance (DSA-AC) have been omitted....
Search Results "Assurances from Contractors"
-
CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS
-
CHAPTER 33 SAFEGUARDS DURING CONSTRUCTION
ETA Editor's Note This Guide contains only the excerpts from California Building Code Chapter 33 that are adopted by Division of the State Architect - Access Compliance (DSA-AC)....
-
CHAPTER 10 MEANS OF EGRESS
ETA Editor's Note Sections from California Building Code Chapter 10 that are not adopted by Division of the State Architect - Access Compliance (DSA-AC) have been omitted....
-
CHAPTER 2 DEFINITIONS
ETA Editor's Note Sections from California Building Code Chapter 2 that are not adopted by Division of the State Architect - Access Compliance (DSA-AC) have been omitted....
-
CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
ETA Editor's Note Sections from California Building Code Chapter 4 that are not adopted by Division of the State Architect - Access Compliance (DSA-AC) have been omitted....
-
CHAPTER 1 SCOPE AND ADMINISTRATION
ETA Editor's Note This Guide contains only the excerpts from California Building Code Chapter 1 that are adopted by Division of the State Architect - Access Compliance (DSA-AC)....
- Washington State Department Of Social And Health Services (DSHS): Division of Vocational Rehabilitation (DVR)
-
11B-604.8.1.2 Doors
Where located in the front partition, the door opening shall be 4 inches (102 mm) maximum from the side wall or partition farthest from the water closet....
-
11B-604.8.1.2 Doors
Where located in the front partition, the door opening shall be 4 inches (102 mm) maximum from the side wall or partition farthest from the water closet....
-
Back Wall: ADA Standard Section 607.4.1.1
Section 607.4.1.1 covers the current ADA Standards for back wall grab bars in bathtubs with permanent seats.
-
11B-809.10.6.5 Thresholds
Where provided thresholds shall be 2 inches (51 mm) maximum in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from the horizontal...
-
11B-809.10.8.1 Location
Lavatories without base cabinets shall be installed with the centerline 18 inches (457 mm) minimum from an adjoining wall or fixture to allow for forward approach....
-
11B-809.10.8.1 Location
Lavatories without base cabinets shall be installed with the centerline 18 inches (457 mm) minimum from an adjoining wall or fixture to allow for forward approach....
-
11B-809.10.6.5 Thresholds
Where provided thresholds shall be 2 inches (51 mm) maximum in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from the horizontal...
-
11B-903.4 Back support
Back support shall be 48 inches (1219 mm) long minimum and shall extend from a point 2 inches (51 mm) maximum above the seat surface to a point 18 inches (457 mm) minimum above the seat...
-
11B-903.4 Back support
Back support shall be 48 inches (1219 mm) long minimum and shall extend from a point 2 inches (51 mm) maximum above the seat surface to a point 18 inches (457 mm) minimum above the seat...
-
BACKGROUND AND JURISDICTION
implementing regulation, a public entity, in providing any aid, benefit, or service, may not: afford qualified individuals with a disability an opportunity to participate in or benefit from...
-
Findings
The following are the predominant findings from this study: No single type of surface material/system was found to be the most accessible surface or better than others when comparing...
-
Section 1194.3 General Exceptions (Preamble, Section-by-Section Analysis)
Section 1194.3 General Exceptions (Preamble, Section-by-Section Analysis) This section provides general exceptions from the standards....
-
11B-607.4.1.1 Back wall
Each grab bar shall be installed 15 inches (381 mm) maximum from the head end wall and 12 inches (305 mm) maximum from the control end wall....
-
11B-607.4.1.1 Back wall
Each grab bar shall be installed 15 inches (381 mm) maximum from the head end wall and 12 inches (305 mm) maximum from the control end wall....
-
Shower Compartment Seats: ADA Standard Section 610.3
Section 610.3 covers the current ADA Standards for shower compartment seats.
-
Identification: ADA Standard Section 809.5.5.2
Such peepholes can be placed at a standard height and permit a view from several feet from the door....
-
Section 36.309 Examinations and Courses (Preamble, Section-by-Section Analysis)
Thus, the provision was included in the ADA in order to assure that persons with disabilities are not foreclosed from educational, professional, or trade opportunities because an examination...