ETA Editor's Note This Guide contains only the excerpts from California Building Code Chapter 31 that are adopted by Division of the State Architect - Access Compliance (DSA-AC)....
Search Results "Assurances from Contractors"
-
CHAPTER 31 SPECIAL CONSTRUCTION
-
CHAPTER 33 SAFEGUARDS DURING CONSTRUCTION
ETA Editor's Note This Guide contains only the excerpts from California Building Code Chapter 33 that are adopted by Division of the State Architect - Access Compliance (DSA-AC)....
-
CHAPTER 31B PUBLIC POOLS
ETA Editor's Note This Guide contains only the excerpts from California Building Code Chapter 31B that are adopted by Division of the State Architect - Access Compliance (DSA-AC)....
-
CHAPTER 30 ELEVATORS AND CONVEYING SYSTEMS
ETA Editor's Note This Guide contains only the excerpts from California Building Code Chapter 30 that are adopted by Division of the State Architect - Access Compliance (DSA-AC)....
-
CHAPTER 2 DEFINITIONS
ETA Editor's Note Sections from California Building Code Chapter 2 that are not adopted by Division of the State Architect - Access Compliance (DSA-AC) have been omitted....
-
CHAPTER 1 SCOPE AND ADMINISTRATION
ETA Editor's Note This Guide contains only the excerpts from California Building Code Chapter 1 that are adopted by Division of the State Architect - Access Compliance (DSA-AC)....
-
CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
ETA Editor's Note Sections from California Building Code Chapter 4 that are not adopted by Division of the State Architect - Access Compliance (DSA-AC) have been omitted....
-
CHAPTER 16A STRUCTURAL DESIGN
ETA Editor's Note This Guide contains only the excerpts from California Building Code Chapter 16A that are adopted by Division of the State Architect - Access Compliance (DSA-AC)....
-
CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS
ETA Editor's Note Sections from California Building Code Chapter 4 that are not adopted by Division of the State Architect - Access Compliance (DSA-AC) have been omitted....
-
11B-703.5.4 Character proportions
Characters shall be selected from fonts where the width of the uppercase letter “O” is 60 percent minimum and 110 percent maximum of the height of the uppercase letter “I”....
-
CHAPTER 16 STRUCTURAL DESIGN
ETA Editor's Note This Guide contains only the excerpts from California Building Code Chapter 16 that are adopted by Division of the State Architect - Access Compliance (DSA-AC)....
-
CHAPTER 16 STRUCTURAL DESIGN
ETA Editor's Note This Guide contains only the excerpts from California Building Code Chapter 16 that are adopted by Division of the State Architect - Access Compliance (DSA-AC)....
-
CHAPTER 31B PUBLIC POOLS
ETA Editor's Note This Guide contains only the excerpts from California Building Code Chapter 31B that are adopted by Division of the State Architect - Access Compliance (DSA-AC)....
-
CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
ETA Editor's Note Sections from California Building Code Chapter 4 that are not adopted by Division of the State Architect - Access Compliance (DSA-AC) have been omitted....
-
CHAPTER 16A STRUCTURAL DESIGN
ETA Editor's Note This Guide contains only the excerpts from California Building Code Chapter 16A that are adopted by Division of the State Architect - Access Compliance (DSA-AC)....
-
CHAPTER 31 SPECIAL CONSTRUCTION
ETA Editor's Note This Guide contains only the excerpts from California Building Code Chapter 31 that are adopted by Division of the State Architect - Access Compliance (DSA-AC)....
-
CHAPTER 30 ELEVATORS AND CONVEYING SYSTEMS
ETA Editor's Note This Guide contains only the excerpts from California Building Code Chapter 30 that are adopted by Division of the State Architect - Access Compliance (DSA-AC)....
-
B. Technical standards for criterion-related validity studies
All criterion measures and the methods for gathering data need to be examined for freedom from factors which would unfairly alter scores of members of any group....
-
Ask Questions and Provide Instructions
., whether or not you would like the airline employee or contractor to push you and the ground wheelchair through the terminal....
-
11B-809.10.6.5 Thresholds
Where provided thresholds shall be 2 inches (51 mm) maximum in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from the horizontal...
-
11B-809.10.8.1 Location
Lavatories without base cabinets shall be installed with the centerline 18 inches (457 mm) minimum from an adjoining wall or fixture to allow for forward approach....
-
Back Wall: ADA Standard Section 607.4.1.1
Section 607.4.1.1 covers the current ADA Standards for back wall grab bars in bathtubs with permanent seats.
-
11B-809.10.6.5 Thresholds
Where provided thresholds shall be 2 inches (51 mm) maximum in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from the horizontal...
-
11B-809.10.8.1 Location
Lavatories without base cabinets shall be installed with the centerline 18 inches (457 mm) minimum from an adjoining wall or fixture to allow for forward approach....