The minimum and maximum height of the gripping surface above the standing surface is based on the provisions for handrails in the 2004 ADA and ABA Accessibility Guidelines....
Search Results "Clearance in Base"
-
Standing Supports (M304.3 and M305.3)
- Populas Accella Adjustable Activity / Computer Workstation
-
11B-603.2.3 Door swing
Doors shall not swing into the clear floor space or clearance required for any fixture. ...
-
¾ Inch Minus and ¼ Inch Minus Limestone
Three Quarter Inch Minus Base and Quarter Inch Minus Top Limestone trail segment is composed of 4 inch base; and a 2 inch top-dressing. August 9, 2007....
-
F201.4.1 Documentation and Notification When Exceptions Used for Trails or Beach Access Routes
This section requires federal agencies to document the basis for not fully complying with a specific provision in the technical requirements for trails on a portion of a trail based on Exception...
-
Wheelchair Spaces (M303.2)
M303.2 includes technical criteria for orientation, width, depth, and knee and toe clearance at wheelchair spaces....
-
11B-306.1 General
Clearances are measured in relation to the usable clear floor space, not necessarily to the vertical support for an element....
-
General [5.1]/ Access Aisles [5.3]
The required clear width (36 inches minimum) is specified for the clearance between the edges of fixed tables or between table edges and walls....
-
11B-306.1 General
Clearances are measured in relation to the usable clear floor space, not necessarily to the vertical support for an element....
-
11B-306.1 General
Clearances are measured in relation to the usable clear floor space, not necessarily to the vertical support for an element....
-
306.1 General
Clearances are measured in relation to the usable clear floor space, not necessarily to the vertical support for an element....
-
608.2.1 Transfer Type Shower Compartments
Clearance of 36 inches (915 mm) wide minimum by 48 inches (1220 mm) long minimum measured from the control wall shall be provided....
-
11B-240.2.1 Ground level play components
Where a stand-alone slide is provided, an accessible route must connect the base of the stairs at the entry point to the exit point of the slide....
-
11B-240.2.1 Ground level play components
Where a stand-alone slide is provided, an accessible route must connect the base of the stairs at the entry point to the exit point of the slide....
-
ACCESS AISLE
[DSA-AC] An accessible pedestrian space adjacent to or between parking spaces that provides clearances in compliance with this code....
-
ACCESS AISLE
[DSA-AC] An accessible pedestrian space adjacent to or between parking spaces that provides clearances in compliance with this code....
-
603.2.2 Overlap
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
-
11B-410.1 General
Because an accessible route requires an 80 inch (2030 mm) vertical clearance, care should be taken in selecting lifts as they may not be equally suitable for use by people using wheelchairs...
-
11B-410.1 General
Because an accessible route requires an 80 inch (2030 mm) vertical clearance, care should be taken in selecting lifts as they may not be equally suitable for use by people using wheelchairs...
- PEMKO 5" Heavy Duty Threshold No. 1715
-
11B-705.1.1.1 Dome size
Truncated domes in a detectable warning surface shall have a base diameter of 0.9 inch (22.9 mm) minimum and 0.92 inch (23.4 mm) maximum, a top diameter of 0.45 inch (11.4 mm) minimum and...
-
Character Height: ADA Standard Section 703.2.5
Character height measured vertically from the baseline of the character shall be 5/8 inch (16 mm) minimum and 2 inches (51 mm) maximum based on the height of the uppercase letter “I”....
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
Transfer Space: ADA Standard Section 1009.5.2
A transfer space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...