Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
Search Results "Clearance in Base"
-
11B-603.2.2 Overlap
-
603.2.2 Overlap
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
-
603.2.2 Overlap
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
-
Paperwork Reduction Act
This rule imposes no new information reporting or recordkeeping necessitating clearance by the Office of Management and Budget....
-
603.2.2 Overlap
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
-
11B-603.2.2 Overlap
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
-
11B-813.2.9 Overlap
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
-
Standing Supports (M304.3 and M305.3)
The minimum and maximum height of the gripping surface above the standing surface is based on the provisions for handrails in the 2004 ADA and ABA Accessibility Guidelines....
-
Keypads: ADA Standard Section 407.4.7.2
Section 407.4.7.2 covers the current ADA Standards for designations and indicators on elevator keypads.
- Pilot Rock WPTS Square Frame Table Using Recycled Plastic
- Pilot Rock WPTS Square Frame Table Using Lumber
-
11B-603.2.3 Door swing
Doors shall not swing into the clear floor space or clearance required for any fixture. ...
-
11B-240.2.1 Ground level play components
Where a stand-alone slide is provided, an accessible route must connect the base of the stairs at the entry point to the exit point of the slide....
-
11B-240.2.1 Ground level play components
Where a stand-alone slide is provided, an accessible route must connect the base of the stairs at the entry point to the exit point of the slide....
- Envirobond is Self-Healing
-
11B-410.1 General
Because an accessible route requires an 80 inch (2030 mm) vertical clearance, care should be taken in selecting lifts as they may not be equally suitable for use by people using wheelchairs...
-
11B-410.1 General
Because an accessible route requires an 80 inch (2030 mm) vertical clearance, care should be taken in selecting lifts as they may not be equally suitable for use by people using wheelchairs...
-
Wheelchair Spaces (M303.2)
M303.2 includes technical criteria for orientation, width, depth, and knee and toe clearance at wheelchair spaces....
-
TTY
Machinery that employs interactive text-based communication through the transmission of coded signals across the telephone network....
-
11B-306.1 General
Clearances are measured in relation to the usable clear floor space, not necessarily to the vertical support for an element....
-
608.2.1 Transfer Type Shower Compartments
Clearance of 36 inches (915 mm) wide minimum by 48 inches (1220 mm) long minimum measured from the control wall shall be provided....
-
306.1 General
Clearances are measured in relation to the usable clear floor space, not necessarily to the vertical support for an element....
-
General [5.1]/ Access Aisles [5.3]
The required clear width (36 inches minimum) is specified for the clearance between the edges of fixed tables or between table edges and walls....
-
11B-306.1 General
Clearances are measured in relation to the usable clear floor space, not necessarily to the vertical support for an element....