Showers required to be accessible shall comply with this section....
Search Results "Shower Room"
-
1134A.6 Showers
-
11B-608.2.2.1 Clearance
A 36 inch (914 mm) wide minimum by 60 inch (1524 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. [2010 ADAS] 608.2.2.1 Clearance....
-
11B-608.2.2.1 Clearance
A 36 inch (914 mm) wide minimum by 60 inch (1524 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment....
-
11B-803.5 Coat hooks and shelves
Coat hooks provided within the room shall be located within one of the reach ranges specified in Section 11B-308....
-
11B-803.5 Coat hooks and shelves
Coat hooks provided within the room shall be located within one of the reach ranges specified in Section 11B-308....
-
Outdoor Rinsing Showers
Outdoor showers permit people to rinse off sand, dirt, and debris. They are not intended for bathing....
-
Coat Hooks and Shelves: ADA Standard Section 222.2
Section 222.2 covers scoping requirements in the current ADA Standards for coat hooks and shelves in dressing, fitting, and locker rooms.
-
608.2.3 Alternate Roll-In Type Shower Compartments
608.2.3 Alternate Roll-In Type Shower Compartments....
-
11B-222.2 Coat hooks and shelves
Where coat hooks or shelves are provided in dressing, fitting or locker rooms without individual compartments, at least one of each type shall comply with Section 11B-803.5....
-
11B-222.2 Coat hooks and shelves
Where coat hooks or shelves are provided in dressing, fitting or locker rooms without individual compartments, at least one of each type shall comply with Section 11B-803.5....
-
11B-224.2.2 More than fifty guest room facilities
Facilities with more than fifty guest rooms shall be treated separately for the purposes of determining the required number of accessible rooms and type of accessible bathing facility....
-
11B-224.2.2 More than fifty guest room facilities
Facilities with more than fifty guest rooms shall be treated separately for the purposes of determining the required number of accessible rooms and type of accessible bathing facility....
-
4.8 Outdoor Rinsing Showers
[See subsections ...]
-
608.5 Controls
Controls, faucets, and shower spray units shall comply with 309.4....
-
Saunas and Steam Rooms: ADA Standard Section 612
Section 612 covers the current ADA Standards for saunas and steam rooms.
-
Toilet and Bathing Rooms: ADA Standard Section 603
Section 603 covers the current ADA Standards for toilet and bathing rooms.
-
11B-610.3.1 Rectangular seats
The rear edge of a rectangular seat shall be 2½ inches (64 mm) maximum and the front edge 15 inches (381 mm) minimum and 16 inches (406 mm) maximum from the seat wall. The side edge...
-
11B-610.3.1 Rectangular seats
The rear edge of a rectangular seat shall be 2½ inches (64 mm) maximum and the front edge 15 inches (381 mm) minimum and 16 inches (406 mm) maximum from the seat wall. The side edge...
-
Location of Controls
Comments indicated that this specification was not consistent with a corresponding figure showing the location on the side closest to the shower opening. Response....
-
4. Shower Wand
Is there an adjustable height hand-held shower wand with at least a 60" long hose provided so persons who bathe from a seated position may wash and rinse with the directional spray?...
-
Bathroom Do’s and Dont’s
Provide a rubber shower mat as an option....
-
11B-608.2.1 Reserved
ETA Editor's Note The transfer type shower compartments prescribed by 2010 ADAS 608.2.1 are not recognized as an accessible shower in California....
-
608.2.3 Alternate Roll-In Type Shower Compartments
Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
Coat Hooks and Shelves: ADA Standard Section 803.5
Coat hooks provided within the room shall be located within one of the reach ranges specified in 308....