11B-608.2.2 Standard roll-in type shower compartments....
Search Results "Shower Room"
-
11B-608.2.2 Standard roll-in type shower compartments
-
11B-805.2.4 Toilet and bathing rooms
Where provided, one water closet, one lavatory, and one bathtub or shower shall comply with the applicable requirements of Sections 11B-603 through 11B-610....
-
11B-805.2.4 Toilet and bathing rooms
Where provided, one water closet, one lavatory, and one bathtub or shower shall comply with the applicable requirements of Sections 11B-603 through 11B-610....
-
11B-805.2.4 Toilet and bathing rooms
Where provided, one water closet, one lavatory, and one bathtub or shower shall comply with the applicable requirements of Sections 11B-603 through 11B-610....
-
Transfer Compartments
Seats are required in transfer compartments and roll-in showers in transient lodging guest rooms (608.4)....
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
4.21.3 Seat
A seat shall be provided in shower stalls 36 in by 36 in (915 mm by 915 mm) and shall be as shown in Fig. 36....
-
11B-608.2 Size and clearances for shower compartments
Shower compartments shall have sizes and clearances complying with Section 11B-608.2....
-
11B-608.2 Size and clearances for shower compartments
Shower compartments shall have sizes and clearances complying with Section 11B-608.2....
-
11B-608.5.1 Reserved
[2010 ADAS] 608.5.1 Transfer Type Shower Compartments....
-
608.3.1 Transfer Type Shower Compartments
In transfer type compartments, grab bars shall be provided across the control wall and back wall to a point 18 inches (455 mm) from the control wall.
-
11B-222.3 Mirrors
Where mirrors are provided in dressing, fitting or locker rooms without individual compartments, at least one of each type shall comply with Section 11B-803.6....
-
11B-222.3 Mirrors
Where mirrors are provided in dressing, fitting or locker rooms without individual compartments, at least one of each type shall comply with Section 11B-803.6....
-
Shower Spray Controls
Shower Spray Controls....
-
4. Faucet Controls
Are the faucet controls and shower wand positioned on the wall along the side of the shower seat so they are operable from the folding shower seat or from the shower wheelchair?...
-
Benches: ADA Standard Section 803.4
A bench complying with 903 shall be provided within the room....
-
1134A.6 Showers
1134A.6 Showers. Showers required to be accessible shall comply with this section....
-
1134A.6 Showers
Showers required to be accessible shall comply with this section. 1. Size....
-
11B-213.2.3 Unisex (Patient) bathing rooms in medical care and long-term care facilities
Common-use unisex bathing rooms for exclusive patient use not located within patient bedrooms shall contain one shower or one bathtub, one lavatory, and one water closet....
-
11B-213.2.3 Unisex (Patient) bathing rooms in medical care and long-term care facilities
Common-use unisex bathing rooms for exclusive patient use not located within patient bedrooms shall contain one shower or one bathtub, one lavatory, and one water closet....
-
11B-803.4 Benches
A bench complying with Section 11B-903 shall be provided within the room....
-
11B-803.4 Benches
A bench complying with Section 11B-903 shall be provided within the room....
-
11B-223.2.3 On-call rooms
Where physician or staff on-call sleeping rooms are provided, at least 10 percent, but no fewer than one, of the on-call rooms shall provide mobility features complying with Sections 11B...