Where physician or staff on-call sleeping rooms are provided, at least 10 percent, but no fewer than one, of the on-call rooms shall provide mobility features complying with Sections 11B...
Search Results "Shower Room"
-
11B-223.2.3 On-call rooms
-
9.5.2(2)(c)
(c) at least one toilet room for each gender or one unisex toilet room shall have a minimum clear door width of 32 in (815 mm), minimum turning space complying with 4.2.3, one water closet...
-
11B-805.4 Examination, diagnostic and treatment rooms
refer to all patient care areas and include but are not limited to: exam rooms, treatment rooms, imaging rooms, operating rooms, emergency rooms, post anesthesia recovery rooms/units, dialysis...
-
11B-805.4 Examination, diagnostic and treatment rooms
refer to all patient care areas and include but are not limited to: exam rooms, treatment rooms, imaging rooms, operating rooms, emergency rooms, post anesthesia recovery rooms/units, dialysis...
-
11B-603.6 Guest room toilet and bathing rooms
11B-603.6 Guest room toilet and bathing rooms....
-
10. Shower Wand
Is there an adjustable height shower wand with at least a 60" long hose provided for persons who must shower from a seated position?...
-
11B-224.1.4 Guest room toilet and bathing rooms
In transient lodging facilities where toilet and bathing rooms are provided in guest rooms that are not required to provide mobility features complying with Section 11B-806.2, toilet and...
-
11B-224.1.4 Guest room toilet and bathing rooms
Where toilet and bathing rooms are provided in guest rooms that are not required to provide mobility features complying with Section 11B-806.2, toilet and bathing fixtures shall only be...
-
Example of a Single-User Bathroom (with Roll-in Shower)
Since wheelchair access precludes curbs at roll-in showers, the shower area and clear floor space can be used for turning....
-
11B-608.3.1 Transfer type shower compartments
In transfer type compartments, grab bars shall be provided across the control wall and back wall to a point 18 inches (457 mm) from the control wall.
-
11B-608.5 Controls
Controls, faucets, and shower spray units shall comply with Section 11B-309.4 _|Operation|_. Controls and faucets shall be of a single-lever design. [2010 ADAS] 608.5 Controls. ...
-
11B-608.5 Controls
Controls, faucets, and shower spray units shall comply with Section 11B-309.4 _|Operation|_. Controls and faucets shall be of a single-lever design. [2010 ADAS] 608.5 Controls....
-
11B-608.2.2.1 Clearance
A 36 inch (914 mm) wide minimum by 60 inch (1524 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. [2010 ADAS] 608.2.2.1 Clearance. ...
-
11B-224.2.1 Fifty or less guest room facilities
Facilities that are subject to the same permit application on a common site that each have fifty or fewer guest rooms may be combined for the purposes of determining the required number...
-
11B-224.2.1 Fifty or less guest room facilities
Facilities that are subject to the same permit application on a common site that each have fifty or fewer guest rooms may be combined for the purposes of determining the required number...
-
11B-603.6 Guest room toilet and bathing rooms
Toilet and bathing rooms within guest rooms that are not required to provide mobility features complying with Section 11B-806.2 shall provide all toilet and bathing fixtures in a location...
-
11B-603.6 Guest room toilet and bathing rooms
Toilet and bathing rooms within guest rooms that are not required to provide mobility features complying with Section 11B-806.2 shall provide all toilet and bathing fixtures in a location...
-
1c
Is there a 36" wide by 48" long clear floor space directly outside the shower for persons who use wheelchairs to approach and use the shower as shown in Figure 35(a) above?...
-
1d
Does the 36" x 48" clear floor space directly outside the shower extend at least 12" past the seat wall of the shower to allow for a seat-to-seat transfer from the wheelchair?...
-
4.21.3 SEAT
A seat shall be provided in shower stalls 36 in by 36 in (915 mm by 915 mm) and shall be as shown in Fig. 36....
-
4.8.1 General
Outdoor rinsing showers shall provide a hand-held shower spray unit complying with ABAAS section 608.6....
-
§ 35.151(e)(2)
(2) Facilities with more than 50 beds covered by this section that provide common use bathing facilities shall provide at least one roll-in shower with a seat that complies with the relevant...
- Access-Able Designs Stationary Dressing Bench DST-101
-
11B-608.5 Controls
Controls, faucets, and shower spray units shall comply with Section 11B-309.4. Controls and faucets shall allow the user to close and open the water supply....