Where toilet rooms are provided, each toilet room shall comply with Section 11B-603. Where bathing rooms are provided, each bathing room shall comply with Section 11B-603....
Search Results "Shower Room"
Commonly Searched Documents
-
11B-213.2 Toilet rooms and bathing rooms
-
Vanity Counter Top Space: ADA Standard Section 806.2.4.1
If vanity counter top space is provided in non-accessible guest toilet or bathing rooms, comparable vanity counter top space, in terms of size and proximity to the lavatory, shall also be...
-
11B-806.2.4.1 Vanity counter top space
If vanity counter top space is provided in non-accessible guest toilet or bathing rooms, comparable vanity counter top space, in terms of size and proximity to the lavatory, shall also be...
-
213.2 Toilet Rooms and Bathing Rooms
213.2 Toilet Rooms and Bathing Rooms. Where toilet rooms are provided, each toilet room shall comply with 603....
- Access-Able Designs Adult Dressing Bench D-101-42
-
F213.2 Toilet Rooms and Bathing Rooms
Where toilet rooms are provided, each toilet room shall comply with 603. Where bathing rooms are provided, each bathing room shall comply with 603. EXCEPTIONS: 1. ...
-
213.2 Toilet Rooms and Bathing Rooms
Where toilet rooms are provided, each toilet room shall comply with 603. Where bathing rooms are provided, each bathing room shall comply with 603. EXCEPTIONS: 1....
-
Verify Framing
Maneuvering clearances/landings at doors. 11B-404 Distance between doors in series. 11B-404.2.6 Grab bar backing in toilet/shower...
-
Verify Framing
Maneuvering clearances/landings at doors. 11B-404 Distance between doors in series. 11B-404.2.6 Grab bar backing in toilet/shower...
-
4.21.4 Grab Bars
ADAAG specifies grab bars on the three walls of a roll-in shower stall, 33"-36" above the floor. The plans reviewed offered little insight as to placement of grab bars in showers....
-
11B-213.2.2 Unisex (Patient) toilet rooms in medical care and long-term care facilities
Common-use unisex toilet rooms for exclusive patient use not located within patient bedrooms shall contain a lavatory and one water closet....
-
1134A.6, Item 1.3
1.3 Other shower stall configurations shall measure at least 36 inches deep by 60 inches wide (914 mm by 1524 mm) with an entrance opening of at least 36 inches (914 mm) when a wall is...
-
1134A.6, Item 1.3
Other shower stall configurations shall measure at least 36 inches deep by 60 inches wide (914 mm by 1524 mm) with an entrance opening of at least 36 inches (914 mm) when a wall is installed...
-
1134A.6, Item 1.2
1.2 The shower stall shall measure at least 30 inches deep by 60 inches wide (762 mm by 1524 mm) with an entrance opening of at least 60 inches (1524 mm)....
-
F206.5.3 Transient Lodging Facilities
In transient lodging facilities, entrances, doors, and doorways providing user passage into and within guest rooms that are not required to provide mobility features complying with 806.2...
-
206.5.3 Transient Lodging Facilities
In transient lodging facilities, entrances, doors, and doorways providing user passage into and within guest rooms that are not required to provide mobility features complying with 806.2...
-
Is turning space required in all rooms and spaces?
Turning space is required in certain spaces, such as toilet and bathing facilities, dressing and fitting rooms, and transient lodging guest rooms....
-
610 Seats
Requirements for bathtub and shower seats are provided in section 610. Comment. Specifications are provided for rectangular and L-shaped shower seats (610.3)....
-
206.5.3 Transient Lodging Facilities
In transient lodging facilities, entrances, doors, and doorways providing user passage into and within guest rooms that are not required to provide mobility features complying with 806.2...
- Access Board: Standard Roll In Shower Stalls
- Access Board: Alternate Type Roll In Shower Stalls
-
If I lease my medical office space, am I responsible for making sure the examination room, waiting room, and toilet rooms are accessible?
Q If I lease my medical office space, am I responsible for making sure the examination room, waiting room, and toilet rooms are accessible? Yes....
-
11B-224.2.2 More than fifty guest room facilities
TABLE 11B-224.2 GUEST ROOMS WITH MOBILITY FEATURES Total Number Of Guest Rooms Provided Minimum Number Of Required Rooms Without Roll-in Showers Minimum...
-
11B-224.4 Guest rooms with communication features
In transient lodging facilities, guest rooms with communication features complying with Section 11B-806.3 shall be provided in accordance with Table 11B-224.4....