The rear edge of an L-shaped seat shall be 2½ inches (64 mm) maximum and the front edge 15 inches (381 mm) minimum and 16 inches (406 mm) maximum from the seat wall. The rear edge of...
Search Results "Shower Room"
-
11B-610.3.2 L-shaped seats
-
11B-610.3.2 L-shaped seats
The rear edge of an L-shaped seat shall be 2½ inches (64 mm) maximum and the front edge 15 inches (381 mm) minimum and 16 inches (406 mm) maximum from the seat wall. The rear edge of...
-
608.4 Seats (Exception)
608.4 Seats (Exception) This section requires a folding or non-folding seat to be provided in transfer type shower compartments....
-
6.4 Patient Toilet Rooms
Where toilet/bath rooms are provided as a part of a patient bedroom, each patient bedroom that is required to be accessible shall have an accessible toilet/bath room that complies with 4.22...
-
11B-809.4.1 Subsequent bathrooms
In residential dwelling units with more than one bathroom, when a bathtub is installed in the first bathroom in compliance with Section 11B-809.4 and a shower compartment is provided in...
-
11B-809.4.1 Subsequent bathrooms
In residential dwelling units with more than one bathroom, when a bathtub is installed in the first bathroom in compliance with Section 11B-809.4 and a shower compartment is provided in...
-
11B-608.5.1 Reserved
[See subsections ...]
-
11B-213.3 Plumbing fixtures and accessories
Plumbing fixtures and accessories provided in a toilet room or bathing room required to comply with Section 11B-213.2 shall comply with Section 11B-213.3. ...
-
11B-213.3 Plumbing fixtures and accessories
Plumbing fixtures and accessories provided in a toilet room or bathing room required to comply with Section 11B-213.2 shall comply with Section 11B-213.3. ...
-
11B-213.3 Plumbing fixtures and accessories
Plumbing fixtures and accessories provided in a toilet room or bathing room required to comply with Section 11B-213.2 shall comply with Section 11B-213.3....
-
Rest Rooms
Rest Rooms • Each public and common use (including employee) rest room must be accessible. This includes rest rooms in work areas and rest rooms located in sky boxes and suites....
-
11B-809.10.6.5 Thresholds
Where provided thresholds shall be 2 inches (51 mm) maximum in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from the...
-
Accessible Patient Rooms
not expected to use adjoining toilet rooms....
-
4.34.5.6 BATHTUB AND SHOWER ENCLOSURES
Enclosures for bathtubs or shower stalls shall not obstruct controls or transfer from wheelchairs onto shower or bathtub seats....
-
III-7.5190 Dressing and fitting rooms
III−7.5190 Dressing and fitting rooms (ADAAG §4.1.3(21)). Where dressing rooms are provided, five percent or at least one must be accessible....
-
Transient Lodging Guest Rooms: ADA Standard Section 806
[See subsections ...]
-
11B-241 Saunas and steam rooms
[See subsections ...]
-
11B-241 Saunas and steam rooms
[See subsections ...]
-
2e
Is there a horizontal grab bar along each of the three shower walls at 33"-36" above the floor as shown in Figure 37(b) below?...
- Seton ADA Braille Signs - Unisex Rest Room 17443
-
1134A.6, Item 2
The maximum slope of the shower floor shall be ½ inch (12.7 mm) per foot in any direction and shall slope to a drain....
-
1134A.6, Item 2
The maximum slope of the shower floor shall be ½ inch (12.7 mm) per foot in any direction and shall slope to a drain....
-
6.4 PATIENT TOILET ROOMS
Provide each patient bedroom that is required to be accessible with an accessible toilet room that complies with 4.22 or 4.23....
-
Room Dimensions
Room Dimensions ADAAG does not specify room dimensions; these vary according to the number and configuration of fixtures, room layout, and the way various spatial requirements are met...