not limited to, remodeling, renovation, rehabilitation, reconstruction, historic restoration, change in surface of circulation paths or vehicular ways, changes or rearrangement of the structural...
Search Results "Feasibility (Technical, Infeasible, Structural, Maximum Extent)"
-
Alteration of a recreation site, building, or facility
-
5.3.6 Entrance
Exception: Where bedrock, perma-frost or other environmental conditions prohibit a level entry or the toilet design (such as a composting toilet) necessitates a raised toilet structure,...
-
TEMPORARY
Structures directly associated with the actual processes of major construction, such as porto potties, scaffolding, bridging, trailers, and the like, are not included....
-
Does the ADA require barrier removal in historic buildings?
However, the ADA takes into account the national interest in preserving significant historic structures....
-
§ 35.150(d)(1)
(1) In the event that structural changes to facilities will be undertaken to achieve program accessibility, a public entity that employs 50 or more persons shall develop, within six months...
-
1.1.8.2 Locally adopted energy standards - California Energy Code, Part 6
provisions of Section 1.1.8.1 of this part, the provisions of this section shall apply to a city, county, and city and county adopting local energy standards applicable to buildings and structures...
-
1.1.8.2 Locally adopted energy standards - California Energy Code, Part 6.
provisions of Section 1.1.8.1 of this part, the provisions of this section shall apply to a city, county, and cities and counties adopting local energy standards applicable to buildings and structures...
-
11B-303.5 Warning curbs
A warning curb is not required when a guard or handrail is provided with a guide rail centered 2 inches (51 mm) minimum and 4 inches (102 mm) maximum above the surface of the walk or sidewalk...
-
11B-410.6 Doors and gates
Exception: Platform lifts serving two landings maximum and having doors or gates on opposite sides shall be permitted to have self-closing manual doors or gates....
-
11B-1008.4.3 Play tables
The tops of rims, curbs, or other obstructions shall be 31 inches (787 mm) high maximum....
-
11B-410.6 Doors and gates
Exception: Platform lifts serving two landings maximum and having doors or gates on opposite sides shall be permitted to have self-closing manual doors or gates....
-
11B-1008.4.3 Play tables
The tops of rims, curbs, or other obstructions shall be 31 inches (787 mm) high maximum....
-
11B-303.5 Warning curbs
A warning curb is not required when a guard or handrail is provided with a guide rail centered 2 inches (51 mm) minimum and 4 inches (102 mm) maximum above the surface of the walk or sidewalk...
-
703.2.7 Character Spacing
Where characters have rectangular cross sections, spacing between individual raised characters shall be 1/8 inch (3.2 mm) minimum and 4 times the raised character stroke width maximum....
-
11B-705.1.2.2 Curb ramps
Detectable warnings shall extend the full width of the ramp run less 2 inches (51 mm) maximum on each side, excluding any flared sides....
-
703.2.7 Character Spacing
Where characters have rectangular cross sections, spacing between individual raised characters shall be 1/8 inch (3.2 mm) minimum and 4 times the raised character stroke width maximum....
-
703.2.7 Character Spacing
Where characters have rectangular cross sections, spacing between individual raised characters shall be 1/8 inch (3.2 mm) minimum and 4 times the raised character stroke width maximum....
-
703.2.7 Character Spacing
Where characters have rectangular cross sections, spacing between individual raised characters shall be 1/8 inch (3.2 mm) minimum and 4 times the raised character stroke width maximum....
-
Running Slope [1018.7.1]
When the running slope of a segment of beach access route is steeper than 1:20 (5 percent), the maximum length of the segment is specified in table 6, and a resting interval must be provided...
-
407.8.3.2.2 Knee and Toe Space under ICT with Obstructed Forward Reach
Knee and toe space under ICT shall be 27 inches (685 mm) high minimum, 25 inches (635 mm) deep maximum, and 30 inches (760 mm) wide minimum and shall be clear of obstructions....
-
604.2 Location
The centerline of the water closet shall be 16 inches (405 mm) minimum to 18 inches (455 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (430...
-
11B-705.1.2.2 Curb ramps
Detectable warnings shall extend the full width of the ramp run less 2 inches (51 mm) maximum on each side, excluding any flared sides....
-
11B-703.2.7 Character spacing
Where characters have rectangular cross sections, spacing between individual raised characters shall be 1/8 inch (3.2 mm) minimum and 4 times the raised character stroke width maximum....
-
11B-703.2.7 Character spacing
Where characters have rectangular cross sections, spacing between individual raised characters shall be 1/8 inch (3.2 mm) minimum and 4 times the raised character stroke width maximum....