(Thus, IDIQ contracts may include items that do not meet the applicable technical provisions of the Access Board’s standards; however, any task or delivery order issued for those items must...
Search Results "Feasibility (Technical, Infeasible, Structural, Maximum Extent)"
Commonly Searched Documents
-
H.1. - What contract actions must satisfy Section 508?
-
4.1.5 Accessible Buildings: Additions
space or element added to the existing building or facility shall comply with the applicable provisions of 4.1.1 to 4.1.3, Minimum Requirements (for New Construction) and the applicable technical...
-
4.1.7(3)(e)
NOTE: The technical provisions of sections 4.2 through 4.35 are the same as those of the American National Standard Institute’s document A117.1‒1980, except as noted in the text....
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
Handrails
Handrails Pool stairs must have handrails with a minimum width between the rails of 20 inches and a maximum of 24 inches....
-
610.2 Bathtub Seats
The top of bathtub seats shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the bathroom finish floor....
-
Accessible Routes Adjacent to the Playing Surface
The accessible route provisions in ADAAG address slope (maximum of 1:12 or 8.33%), width (minimum of 36 inches), cross slope (maximum of 1:50 or 2%), handrails, and changes in level....
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
Allowances for Typical Roadway Geometry
Allowances for Typical Roadway Geometry The 1991 ADAAG and 2004 ADA and ABA Accessibility Guidelines specify a maximum running slope of 5 percent and maximum cross slope of 2 percent...
-
Opening Force [§404.2.9]
Opening Force [§404.2.9] The maximum 5 lbf opening force applies to all accessible doors and gates except: fire doors (minimum opening force allowed by code) exterior...
- Sioux Chief DropKick™ Offset Flange 889-45PAM
- Sioux Chief FullFlush™ Offset Flange 889-AOM
-
Camping Units
When work is done to improve an existing camping or picnic facility or a trailhead and a condition for an exception prohibits full compliance with a specific technical requirement on part...
- Council of Citizens with Low Vision International (CCLVI)
- National Amputation Foundation
-
11B-409.4.3 Platform to hoistway clearance
The clearance between the car platform and the edge of any landing sill shall be 1½ inch (38 mm) maximum....
-
703.2.6 Stroke Thickness
Stroke thickness of the uppercase letter "I" shall be 15 percent maximum of the height of the character....
-
11B-410.4 Platform to runway clearance
The clearance between the platform sill and the edge of any runway landing shall be 1¼ inch (32 mm) maximum....
-
1008.2.5.2 Elevated
The rise for any ramp run connecting elevated play components shall be 12 inches (305 mm) maximum....
-
410.4 Platform to Runway Clearance
The clearance between the platform sill and the edge of any runway landing shall be 1 inch (32 mm) maximum....
-
409.4.3 Platform to Hoistway Clearance
The clearance between the car platform and the edge of any landing sill shall be 1-½ inch (38 mm) maximum....
-
703.5.7 Stroke Thickness
Stroke thickness of the uppercase letter "I" shall be 10 percent minimum and 30 percent maximum of the height of the character....
-
703.5.7 Stroke Thickness
Stroke thickness of the uppercase letter "I" shall be 10 percent minimum and 30 percent maximum of the height of the character....