Space at least 30 by 48 inches is the minimum required for a person using a wheelchair....
Search Results "Clear Floor Space"
-
Space Allowance and Reach Ranges [4.2]
-
309.2 Clear Floor Space
A clear floor or ground space complying with 305 shall be provided....
-
Clear Floor Space [4.2.4]
Clearances are measured in relation to the usable clear floor space, not necessarily to the vertical support....
-
Forward Reach [4.2.5]
Forward reaches are measured to the edge of available clear floor space. This accommodates high and low reaches and assumes some forward bending....
-
409.4.1 Inside Dimensions of Elevator Cars
Elevator cars shall provide a clear floor space of 36 inches (915 mm) minimum by 48 inches (1220 mm) minimum and shall comply with 305....
-
Side Reach [4.2.6]
High and low reaches are based on a depth of reach no greater than 10 inches measured from the available clear floor space....
-
410.3 Clear Floor Space
410.3 Clear Floor Space. Clear floor space in platform lifts shall comply with 305....
-
4.15.5(1)
(1) Wall- and post-mounted cantilevered units shall have a clear knee space between the bottom of the apron and the floor or ground at least 27 in (685 mm) high, 30 in (760 mm) wide, and...
-
4.15.5(1)
(1) Wall- and post-mounted cantilevered units shall have a clear knee space between the bottom of the apron and the floor or ground at least 27 in (685 mm) high, 30 in (760 mm) wide, and...
-
4.15.5(2)
(2) Free standing or built-in units not having a clear space under them shall have a clear floor space at least 30 in by 48 in (760 mm by 1220 mm) that allows a person in a wheelchair to...
-
4.15.5(2)
(2) Free-standing or built-in units not having a clear space under them shall have a clear floor space at least 30 in by 48 in (760 mm by 1220 mm) that allows a person in a wheelchair to...
-
4.20.2 FLOOR SPACE
Clear floor space in front of bathtubs shall be as shown in Fig. 33....
-
4.20.2 Floor Space
Clear floor space in front of bathtubs shall be as shown in Fig. 33....
-
Side Approach
Side Approach Clear space for a side approach is specified for units that are free-standing or built-in....
-
4.22.2 Doors
Doors shall not swing into the clear floor space required for any fixture....
-
4.22.2 DOORS
Doors shall not swing into the clear floor space required for any fixture....
-
4.23.2 Doors
Doors shall not swing into the floor space required for any fixture....
-
4.23.2 DOORS
Doors shall not swing into the floor space required for any fixture....
-
4.23.3 CLEAR FLOOR SPACE
The clear floor spaces at fixtures and controls, the accessible route, and the turning space may overlap....
-
4.23.3* Clear Floor Space
An unobstructed turning space complying with 4.2.3 shall be provided within an accessible bathroom....
-
4.24.5 CLEAR FLOOR SPACE
A clear floor space at least 30 in by 48 in (760 mm by 1220 mm) complying with 4.2.4 shall be provided in front of a sink to allow forward approach....
-
4.24.5 Clear Floor Space
A clear floor space at least 30 in by 48 in (760 mm by 1220 mm) complying with 4.2.4 shall be provided in front of a sink to allow forward approach....
-
4.25.2 Clear Floor Space
A clear floor space at least 30 in by 48 in (760 mm by 1220 mm) complying with 4.2.4 that allows either a forward or parallel approach by a person using a wheelchair shall be provided at...