Common Questions
Search Results "Clear Floor Space"
-
Common Questions (Clear Floor or Ground Space and Turning Space)
-
Is clear floor space required to be centered on elements?
The standards require the clear floor space to be centered on wheelchair accessible drinking fountains (forward approach), kitchen work surfaces, (forward approach), and washers and dryers...
-
Can doors swing into required clear floor or ground space?
Doors cannot swing into required clear floor or ground spaces in these specific instances: clear floor space at controls for automatic and power assisted doors and gates (404.3.5...
-
Can clear floor/ground space or turning space overlap other space requirements?
Yes, clear floor or ground spaces and turning space can overlap other required clearances, including other clear floor spaces, door maneuvering clearances, and fixture clearances....
-
H12
For at least one of each type of dispenser, receptacle, or equipment, is there clear floor space at least 30 inches wide x 48 inches long adjacent to the control or dispenser (positioned...
-
H13
Is the operating control (switch, lever, button, or pull) of at least one of each type of dispenser or built-in equipment no higher than 54 inches above the floor (if there is clear floor...
-
Forward and Side Approaches
At most elements, clear floor space can be positioned for either a forward approach or a side approach....
-
Clear Floor Space [§309.2]
Clear Floor Space [§309.2] Clear floor space for forward approaches must extend up to or, if knee or toe space is provided, below operable parts....
-
Clear Floor Space [§309.2]
Clear Floor Space [§309.2] Clear floor space can be oriented for a side approach instead of a forward approach at most operable parts....
-
3.3.3 Clear Floor Width
3.3.3 Clear Floor Width The findings on clear floor width are based on the findings on occupied width from anthropometric studies shown in Figure 3‒3....
-
3.3.4 Clear Floor Length
3.3.4 Clear Floor Length The mean value of clear floor length for our study (1250 mm or 49 in.) is above the clear floor length provided in the U.S. standards (1220 mm or 48 in.)....
-
Clear Floor or Ground Space
Clear Floor or Ground Space At least one clear floor or ground space (30 inches by 48 inches minimum) must be provided at each location that has a railing height of 34 inches maximum....
-
I1a
For a side approach (clear floor space at least 30 inches long x 48 inches wide), is the coin slot no higher than 54 inches above the floor?...
-
Forward Approach
For wheelchair access, the proposed rule required a forward approach at cantilevered units but allowed a parallel approach at other types of units, such as those that are floor mounted....
-
I1b
For a front approach (where clear floor space at least 30 inches wide x 48 inches long), is the coin slot no higher than 48 inches above the floor?...
-
§382.57(c)(2) Clear floor or ground space
(2) Clear floor or ground space. A clear floor or ground space complying with section 305 of the U.S....
-
404.3.5 Controls
The clear floor space adjacent to the control shall be located beyond the arc of the door swing....
-
305 Clear Floor or Ground Space
305 Clear Floor or Ground Space...
-
J1
If the drinking fountain is a wall-mounted unit, is there clear floor space at least 30 inches wide (36 inches if it is in an alcove) x 48 inches long in front of the drinking fountain and...
-
305.1 General
Clear floor or ground space shall comply with 305....
-
J2
If the drinking fountain is a floor-mounted unit, is there clear floor space at least 30 inches long x 48 inches wide (60 inches if it is in an alcove) for a side approach to the drinking...
-
305.2 Floor or Ground Surfaces
305.2 Floor or Ground Surfaces. Floor or ground surfaces of a clear floor or ground space shall comply with 302. Changes in level are not permitted....
-
305.3 Size
The clear floor or ground space shall be 30 inches (760 mm) minimum by 48 inches (1220 mm) minimum. Figure 305.3 Clear Floor or Ground Space...