Unless otherwise specified, clear floor or ground space shall be permitted to include knee and toe clearance complying with 306....
Search Results "Clear Floor Space"
-
305.4 Knee and Toe Clearance
-
305.5 Position
Unless otherwise specified, clear floor or ground space shall be positioned for either forward or parallel approach to an element. ...
-
305.6 Approach
One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space....
-
305.7 Maneuvering Clearance
Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance shall be provided in accordance with 305.7.1...
-
305.7.1 Forward Approach
305.7.1 Forward Approach. Alcoves shall be 36 inches (915 mm) wide minimum where the depth exceeds 24 inches (610 mm). Figure 305.7.1 Maneuvering Clearance in an Alcove,...
-
305.7.2 Parallel Approach
305.7.2 Parallel Approach. Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm). Figure 305.7.2 Maneuvering Clearance in an Alcove,...
-
Clear Floor Space
The minimum unobstructed floor or ground space required to accommodate a single, stationary wheelchair and occupant....
-
306.1 General
Where space beneath an element is included as part of clear floor or ground space or turning space, the space shall comply with 306....
-
407.2.1.3 Clear Floor or Ground Space
A clear floor or ground space complying with 305 shall be provided at call controls. Advisory 407.2.1.3 Clear Floor or Ground Space....
-
Space Needs
Percentage of subjects who were able to transfer within each clear floor space dimension for Protocol A transfer TO and FROM the platform at their maximum height (Max) and minimum height...
-
Problem One (Voting Area)
Solution: Relocate the voting area to a larger space such as a hallway or lobby or change the layout of the voting area by moving the check-in table outside the room to provide appropriate...
-
309.2 Clear Floor Space
309.2 Clear Floor Space. A clear floor or ground space complying with 305 shall be provided....
-
409.4.1 Inside Dimensions of Elevator Cars
Elevator cars shall provide a clear floor space of 36 inches (915 mm) minimum by 48 inches (1220 mm) minimum and shall comply with 305....
-
Wheelchair Space for Seat Transfer
Commenters indicated that this provision could be misinterpreted as allowing the space to be provided in front of the bench at one end....
-
410.3 Clear Floor Space
Clear floor space in platform lifts shall comply with 305....
-
F224.3 Beds
In guest rooms having more than 25 beds, 5 percent minimum of the beds shall have clear floor space complying with 806.2.3....
-
F232.2.1.1 Beds
In cells having more than 25 beds, at least 5 percent of the beds shall have clear floor space complying with 807.2.3....
-
§ 382.57(c)(2) Clear floor or ground space
(2) Clear floor or ground space. A clear floor or ground space complying with section 305 of the U.S....
-
4.2 Clear Floor Area
4.2 Clear Floor Area Figure 9 and Table 3 show the standards from the four countries related to clear floor area. Figures 10-13 show the key findings from the research....
-
Controls [§404.3.5]
Clear floor space at controls must be located outside the door swing to prevent users from getting hit by the door....
-
4.2.4* CLEAR FLOOR OR GROUND SPACE FOR WHEELCHAIRS
-
4.2.4* Clear Floor or Ground Space for Wheelchairs.