Secondary exterior door thresholds, including sliding door tracks, shall be 3/4 inch (19.1 mm) high maximum with a 1:2 maximum slope....
Search Results "Shower Door"
Commonly Searched Documents
-
11B-809.8.1 Door Thresholds
-
Plan 5A: 13-Foot Wide Accessible Guest Room
Features include a transfer shower, comparable vanity, clothes closet with swinging door, and door connecting to adjacent guest room....
-
General: ADA Standard Section 404.1
Section 404.1 of the ADA Standards covers information in the current ADA Standards for doors, doorways, and gates that are part of an accessible route.
-
Doors, Doorways, and Gates: ADA Standard Section 404
Section 404 covers the current ADA Standards for doors, doorways, and gates that are part of an accessible route.
-
608.3.1 Transfer Type Shower Compartments
Figure 608.3.1 Grab Bars for Transfer Type Showers...
-
11B-304.4 Door swing
Doors shall be permitted to swing into turning spaces....
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain....
-
Elevator Doors: ADA Standard Section 408.3
Section 408.3 covers the current ADA Standards for limited-use/limited-application elevator doors.
-
4.20.6 SHOWER UNIT
A shower spray unit with a hose at least 60 in (1525 mm) long that can be used as a fixed shower head or as a hand-held shower shall be provided....
-
4.20.6 Shower Unit
A shower spray unit with a hose at least 60 in (1525 mm) long that can be used both as a fixed shower head and as a hand-held shower shall be provided....
-
Sliding Doors: ADA Standard Section 408.3.1
Section 408.3.1 covers the current ADA Standards for limited-use/limited-application elevator sliding doors.
-
Swinging Doors: ADA Standard Section 408.3.2
Section 408.3.1 covers the current ADA Standards for limited-use/limited-application elevator swinging doors.
-
Alternative Designs. Bathroom as Shower Room
Bathroom as Shower Room....
-
A4.21.1 GENERAL
Shower stalls that are 36 in by 36 in (915 mm by 915 mm) wide provide additional safety to people who have difficulty maintaining balance because all grab bars and walls are within easy...
-
11B-404 Doors, doorways, and gates
[See subsections ...]
-
608 Shower Compartments
Section 608 addresses transfer showers and roll-in showers and provides specifications for size and clearances, grab bars, seats, operable parts, shower spray units, thresholds, and enclosures...
-
Plan 2B: 13-Foot Wide Accessible Guest Room
Features include an alternate roll-in shower with a seat, comparable vanity, wardrobe, and door connecting to adjacent guest room. Furnishings include two beds. ...
-
404.2.4.2 Doorways without Doors or Gates, Sliding Doors, and Folding Doors
Doorways less than 36 inches (915 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 404.2.4.2....
-
11B-404.3.5 Controls
The clear floor space adjacent to the control shall be located beyond the arc of the door swing. Advisory 11B-404.3.5 Controls. ...
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
Doorways less than 36 inches (914 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 11B-404.2.4.2....
-
11B-608.6 Shower spray unit and water
SECTION TITLE NOTES 11B-608.6 Shower spray unit and water....
-
11B-608.9 Shower floor or ground surface
11B-608.9 Shower floor or ground surface. Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction....
-
Plan 5B: 13-Foot Wide Accessible Guest Room
Features include a transfer shower, comparable vanity, open clothes closet, and door connecting to adjacent guest room. Furnishings include two beds. ...
-
Error/Omission: In hotels, motels, or other lodging facilities of 50 or more sleeping rooms, no rooms with roll-in showers are provided, or the roll-in showers that are provided lack a fold-down seat.
Error/Omission: In hotels, motels, or other lodging facilities of 50 or more sleeping rooms, no rooms with roll-in showers are provided, or the roll-in showers that are provided lack...