Doorways less than 36 inches (914 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 11B-404.2.4.2....
Search Results "Shower Door"
Commonly Searched Documents
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
-
11B-608.6 Shower spray unit and water
SECTION TITLE NOTES 11B-608.6 Shower spray unit and water....
-
11B-608.9 Shower floor or ground surface
11B-608.9 Shower floor or ground surface. Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction....
-
Automatic and Power-Assisted Doors and Gates: ADA Standard Section 404.3
Section 404.3 covers the current ADA Standards for automatic and power-assisted doors and gates.
-
Error/Omission: In hotels, motels, or other lodging facilities of 50 or more sleeping rooms, no rooms with roll-in showers are provided, or the roll-in showers that are provided lack a fold-down seat.
Error/Omission: In hotels, motels, or other lodging facilities of 50 or more sleeping rooms, no rooms with roll-in showers are provided, or the roll-in showers that are provided lack...
-
Plan 5B: 13-Foot Wide Accessible Guest Room
Features include a transfer shower, comparable vanity, open clothes closet, and door connecting to adjacent guest room. Furnishings include two beds. ...
-
11B-408.3 Elevator doors
Elevator hoistway doors shall comply with Section 11B-408.3....
-
Closing Speed: ADA Standard Section 404.2.8
Section 404.2.8 covers the current ADA Standards for the closing speed of doors.
-
11B-404.2.8 Closing speed
Door and gate closing speed shall comply with Section 11B-404.2.8....
-
11B-407.3.1 Type
Elevator doors shall be the horizontal sliding type. Car gates shall be prohibited....
-
11B-408.3.1 Sliding doors
Sliding hoistway and car doors shall comply with Sections 11B-407.3.1 through 11B-407.3.3 and 11B-408.4.1....
-
4.20.6 Shower Unit
4.20.6 Shower Unit. None of the respondents indicated that there were any variations from ADAAG regarding the shower unit....
-
4.20.6 Shower Unit
4.20.6 Shower Unit. None of the respondents indicated that there were any variations from ADAAG regarding the shower unit....
-
11B-408.3.2 Swinging doors
Swinging hoistway doors shall open and close automatically and shall comply with Sections 11B-404, 11B-407.3.2 and 11B-408.3.2....
-
11B-404.1 General
Doors, doorways, and gates that are part of an accessible route shall comply with Section 11B-404....
-
Error/Omission: When a transfer shower is used, it is often larger than the required 36" x 36" size.
Users may slide off the seat and fall onto the floor of the shower while reaching for the shower controls and hand-held showerhead. Requirement: 4.21.2 Size and Clearances....
-
Are screen doors or storm doors considered “doors in series”?
No, screen or storm doors are not considered “doors in series” since they are part of the same doorway opening as the entry door....
-
Shower
Shower Lowered sidewalls of a roll-in shower. Although not a transfer issue, lowered sidewalls were intended to facilitate assisted showering....
-
608 Shower Compartments
608 Shower Compartments...
-
11B-608.9 Shower floor or ground surface
Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction....
-
11B-608.9 Shower floor or ground surface
Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction....
-
Shower Stalls (ADAAG 4.21)
Shower Stalls (ADAAG 4.21) Although ADAAG permits both transfer and a roll-in showers, roll-in showers were found in institutional facilities....
-
608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (13 mm) high maximum in accordance with 303....
-
608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (13 mm) high maximum in accordance with 303....