2010 ADA Standards for Accessible Design Pocket Guide
404.2.4.3 Recessed Doors and Gates.
Maneuvering clearances for forward approach shall be provided when any obstruction within 18 inches (455 mm) of the latch side of a doorway projects more than 8 inches (205 mm) beyond the face of the door, measured perpendicular to the face of the door or gate. [S.H. 4.13.6]
Advisory 404.2.4.3 Recessed Doors and Gates. A door can be recessed due to wall thickness or because of the placement of casework and other fixed elements adjacent to the doorway. This provision must be applied wherever doors are recessed.
User Comments/Questions
Re: 404.2.4.3 Recessed Doors and Gates
General Comment or Question
Notice that the text does not match the figure for a push approach door. This may be an error in the Standards, but since...
July 02, 2019 at 2:07AM
By James L. Terry - 11 views, 0 replies