[See subsections ...]
Search Results "Shower Door"
Commonly Searched Documents
-
11B-608 Shower compartments
-
Doors and Gates: ADA Standard Section 410.6
Section 410.6 covers the current ADA Standards for the doors and gates of platform lifts.
-
AUTOMATIC DOOR
[DSA-AC] A door equipped with a power operated mechanism and controls that open and close the door automatically upon receipt of a momentary actuating signal....
-
Doors, Doorways, and Gates: ADA Standard Section 206.5
Section 206.5 covers scoping requirements in the most current ADA Standards for accessible routes to doors, doorways, and gates.
-
11B-607.6 Shower spray unit and water
A shower spray unit with a hose 59 inches (1499 mm) long minimum that can be used both as a fixed-position shower head and as a hand-held shower shall be provided....
-
11B-809.8.3 Door maneuvering clearance.
At the dwelling unit side of the primary entry doors, secondary exterior doors, and required exit doors maneuvering clearances shall be 44 inches (1118 mm) minimum in length measured...
-
Doors in Series and Gates in Series: ADA Standard Section 404.2.6
Section 404.2.6 covers the current ADA Standards for doors in series and gates in series.
-
608.5.2 Standard Roll-In Type Shower Compartments
608.5.2 Standard Roll-In Type Shower Compartments....
-
608.5.2 Standard Roll-In Type Shower Compartments
In standard roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
-
608.5.2 Standard Roll-In Type Shower Compartments
In standard roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
-
11B-610.3 Shower compartment seats
11B-610.3 Shower compartment seats....
-
11B-610.3 Shower compartment seats
In transfer-type showers, the seat shall extend from the back wall to a point within 3 inches (76 mm) of the compartment entry....
-
11B-410.6 Doors and gates
Platform lifts shall have low-energy power-operated doors or gates complying with Section 11B-404.3. Doors shall remain open for 20 seconds minimum....
-
Rectangular Seats: ADA Standard Section 610.3.1
Section 610.3.1 covers the current ADA Standards for rectangular shower compartment seats.
-
11B-610.3 Shower compartment seats
A seat in a standard roll-in shower compartment shall be a folding type, shall be installed on the side wall adjacent to the controls, and shall extend from the back wall to a point within...
-
11B-206.5 Doors, doorways, and gates
Doors, doorways, and gates providing user passage shall be provided in accordance with Section 11B-206.5....
-
11B-404.2.6 Doors in series and gates in series
The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches (1219 mm) minimum plus the width of doors or gates swinging into the space....
-
11B-608.5.2 Standard roll-in type shower compartments
In standard roll-in type shower compartments, the controls, faucets, and the shower spray unit shall be located on the back wall of the compartment adjacent to the seat 16 inches (406 mm...
-
11B-608.5.2 Standard roll-in type shower compartments
(991 mm) to 41 inches (1041 mm) above the shower floor....
-
11B-608.5.2 Standard roll-in type shower compartments
11B-608.5.2 Standard roll-in type shower compartments....
-
608.8 Shower Enclosures
608.8 Shower Enclosures. Enclosures for shower compartments shall not obstruct controls, faucets, and shower spray units or obstruct transfer from wheelchairs onto shower seats....
-
Double-Leaf Doors and Gates: ADA Standard Section 404.2.2
Section 404.2.2 covers the current ADA Standards for double-leaf doors and gates that are part of an accessible route.
-
608.8 Shower Enclosures
Enclosures for shower compartments shall not obstruct controls, faucets, and shower spray units or obstruct transfer from wheelchairs onto shower seats....
-
608.8 Shower Enclosures
Enclosures for shower compartments shall not obstruct controls, faucets, and shower spray units or obstruct transfer from wheelchairs onto shower seats. [ECTCR UFAS 4.21.8, 4.34.5.6]...