Thresholds, if provided at doorways, shall be 1/2 inch (13 mm) high maximum. Raised thresholds and changes in level at doorways shall comply with 302 and 303....
Search Results "Expected Maximum Flight Duration"
-
404.2.5 Thresholds
-
404.2.5 Thresholds
Thresholds, if provided at doorways, shall be 1/2 inch (13 mm) high maximum. Raised thresholds and changes in level at doorways shall comply with 302 and 303....
-
407.8.2 Side Reach
The vertical reference plane shall be centered on the operable part and placed at the leading edge of the maximum protrusion of the ICT within the length of the vertical reference plane....
-
407.8.3.2.1 Operable Part Height for ICT with Obstructed Forward Reach
407.8.3.2.1 Operable Part Height for ICT with Obstructed Forward Reach Reach Depth Operable Part Height Less than 20 inches (510 mm) 48 inches (1220 mm) maximum...
-
11B-703.2.4 Character proportions
Characters shall be selected from fonts where the width of the uppercase letter “O” is 60 percent minimum and 110 percent maximum of the height of the uppercase letter “I”....
-
407.12.2 Side Reach
The vertical reference plane shall be centered on the operable part and placed at the leading edge of the maximum protrusion of the ICT within the length of the vertical reference plane....
-
11B-309.4 Operation
The force required to activate operable parts shall be 5 pounds (22.2 N) maximum....
-
11B-309.4 Operation
The force required to activate operable parts shall be 5 pounds (22.2 N) maximum....
-
11B-904.4.1 Parallel approach
A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum above the finish floor shall be provided....
-
11B-604.2 Location
The centerline of the water closet shall be 17 inches (432 mm) minimum to 18 inches (457 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (432...
-
Exterior/ Fire Doors
Exterior/ Fire Doors A maximum opening force is not specified for exterior swing doors because the closing force required by building codes usually exceeds an "accessible" resistance....
-
11B-904.4.1 Parallel approach
A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum above the finish floor shall be provided....
-
11B-604.2 Location
The centerline of the water closet shall be 17 inches (432 mm) minimum to 18 inches (457 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (432...
-
Height Above Finish Floor or Ground: ADA Standard Section 703.4.1
characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches (1525 mm) maximum...
-
Doors and Gates: ADA Standard Section 410.6
Section 410.6 covers the current ADA Standards for the doors and gates of platform lifts.
-
Beveled: ADA Standard Section 303.3
Section 303.3 covers the current ADA Standards for beveled level changes.
-
Location: ADA Standard Section 407.2.1.4
Section 407.2.1.4 covers the current ADA Standards for the location of elevator call controls.
-
Play Tables: ADA Standard Section 1008.4.3
The tops of rims, curbs, or other obstructions shall be 31 inches (785 mm) high maximum....
-
11B-403.5.3 Passing spaces
An accessible route with a clear width less than 60 inches (1524 mm) shall provide passing spaces at intervals of 200 feet (60,960 mm) maximum....
-
1607.9.2 Grab bars, shower seats and accessible benches
designed to resist a single concentrated load of 250 pounds (1.11 kN) applied in any direction at any point on the grab bar, shower seat, or seat of the accessible bench so as to produce the maximum...
-
11B-605.4 Flush controls
Hand operated flush controls shall comply with Section 11B-309 except that the flush control shall be mounted at a maximum height of 44 inches (1118 mm) above the finish floor. ...
-
11B-605.4 Flush controls
Hand operated flush controls shall comply with Section 11B-309 except that the flush control shall be mounted at a maximum height of 44 inches (1118 mm) above the finish floor. ...
-
11B-403.5.3 Passing spaces
An accessible route with a clear width less than 60 inches (1524 mm) shall provide passing spaces at intervals of 200 feet (60,960 mm) maximum....
- Sargent Keypad Mortise Locks