The spout shall provide a flow of water 4 inches (102 mm) high minimum and shall be located 5 inches (127 mm) maximum from the front of the unit....
Search Results "Expected Maximum Flight Duration"
-
11B-602.6 Water flow
-
11B-609.2.2 Non-circular cross section
Grab bars with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (102 mm) minimum and 4.8 inches (122 mm)...
-
11B-505.7.2 Non-circular cross sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (102 mm) minimum and 6¼ inches (159 mm) maximum, and a cross-section dimension of...
-
11B-703.5.7 Stroke thickness
Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 20 percent maximum of the height of the character. [2010 ADAS] 703.5.7 Stroke Thickness....
-
11B-703.7.2.6.4 Edges and vertices on geometric symbols
Edges shall be eased or rounded at 1/16 inch (1.59 mm) minimum, or chamfered at 1/8 inch (3.2 mm) maximum....
-
11B-603.4 Coat hooks, shelves and medicine cabinets
Shelves shall be located 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor....
-
904.3.2 Counter
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....
-
Ramps
For each elevated ramp run: 12-inch (305 mm) maximum rise 1:12 maximum slope 36-inch (915 mm) minimum clear width ...
-
Passing Spaces: ADA Standard Section 403.5.3
Section 403.5.3 covers the current ADA Standards for passing spaces that are part of an accessible route.
-
1607A.9.2 Grab bars, shower seats and accessible benches
designed to resist a single concentrated load of 250 pounds (1.11 kN) applied in any direction at any point on the grab bar, shower seat, or seat of the accessible bench so as to produce the maximum...
-
11B-809.10.7.2 Location
The centerline of the water closet shall be 17 inches (432 mm) minimum to 18 inches (457 mm) maximum from a wall or partition that is 54 inches (1372 mm) minimum in length....
-
11B-809.10.7.2 Location
The centerline of the water closet shall be 17 inches (432 mm) minimum to 18 inches (457 mm) maximum from a wall or partition that is 54 inches (1372 mm) minimum in length....
-
609.2.2 Non-Circular Cross Section
Grab bars with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (100 mm) minimum and 4.8 inches (120 mm)...
-
11B-904.3.2 Counter
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....
-
505.7.2 Non-Circular Cross Sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (100 mm) minimum and 6¼ inches (160 mm) maximum, and a cross-section dimension of...
-
T302.4 Surface Discontinuities
Surface discontinuities shall be ½ inch (13 mm) high maximum and shall be beveled with a slope not steeper than 1:2. EXCEPTIONS: 1....
-
705.1.1 Dome Size
Truncated domes in a detectable warning surface shall have a base diameter of 0.9 inch (23 mm) minimum and 1.4 inches (36 mm) maximum, a top diameter of 50 percent of the base diameter minimum...
-
11B-703.3.1 Dimensions and capitalization
TABLE 11B-703.3.1 BRAILLE DIMENSIONS MEASUREMENT RANGE MINIMUM IN INCHES MAXIMUM IN INCHES Dot base diameter...
-
11B-703.3.1 Dimensions and capitalization
TABLE 11B-703.3.1 BRAILLE DIMENSIONS MEASUREMENT RANGE MINIMUM IN INCHES MAXIMUM IN INCHES Dot base diameter...
-
Re: Slope of R309 On-Street Parking Spaces
The more level they are, the more usable they will be, but a 2.08% maximum slope is not a requirement. Verified by Melissa Anderson at APA conference 2/2/18...
-
505.7.2 Non-Circular Cross Sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (100 mm) minimum and 6¼ inches (160 mm) maximum, and a cross-section dimension of...
-
11B-407.4.10.1 Location
Top of support rails shall be 31 inches (787 mm) minimum to 33 inches (838 mm) maximum above the floor of the car....
-
11B-309.4 Operation
The force required to activate operable parts shall be 5 pounds (22.2 N) maximum....