Truncated domes in a detectable warning surface shall have a center-to-center spacing of 2.3 inches (58 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
Search Results "Expected Maximum Flight Duration"
-
11B-705.1.1.2 Dome spacing
-
24. TRAINING FOR OWNED HOTELS, MANAGED HOTELS, AND JOINT VENTURE HOTELS
All employees required to undergo ADA Training will undergo refresher training every two years for the duration of this Consent Decree....
-
Obligations of The Department
Throughout the duration of this Agreement, the Department may conduct compliance surveys or reviews of the County’s polling places in each election or at any other time with reasonable notice...
-
Press Boxes: ADA Standard Section 206.2.7
Section 206.2.7 covers scoping requirements in the most current ADA Standards for accessible routes to press boxes.
-
11B-206.2.7 Press boxes
accessible route shall not be required to press boxes in bleachers that have points of entry at only one level provided that the aggregate area of all press boxes is 500 square feet (46 m2) maximum...
-
11B-206.2.7 Press boxes
accessible route shall not be required to press boxes in bleachers that have points of entry at only one level provided that the aggregate area of all press boxes is 500 square feet (46 m2) maximum...
-
Shower Spray Controls
accessible bathtubs and shower compartments, sections 607.6 and 608.6 of the 2010 Standards require shower spray controls to have an on/off control and to deliver water that is 120°F (49°C) maximum...
-
R305.1.1 Dome Size
The truncated domes shall have a base diameter of 23 mm (0.9 in) minimum and 36 mm (1.4 in) maximum, a top diameter of 50 percent of the base diameter minimum and 65 percent of the base...
-
R302.7.4 Flangeway Gaps
Flangeway gaps at pedestrian at-grade rail crossings shall be 64 mm (2.5 in) maximum on non-freight rail track and 75 mm (3 in) maximum on freight rail track....
-
4.8.2* SLOPE AND RISE
The maximum slope of a ramp in new construction shall be 1:12. The maximum rise for any run shall be 30 in (760 mm) (see Fig. 16)....
-
11B-608.5.1 Reserved
transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm) maximum...
-
11B-403.7 Continuous gradient
All walks with continuous gradients shall have resting areas, 60 inches (1524 mm) in length, at intervals of 400 feet (121,920 mm) maximum....
-
11B-705.1.2.2.2 Parallel curb ramps
Detectable warnings at parallel curb ramps shall be located so the edge nearest the curb is 6 inches (152 mm) minimum and 8 inches (203 mm) maximum from the demarcation line at the face...
-
11B-403.7 Continuous gradient
All walks with continuous gradients shall have resting areas, 60 inches (1524 mm) in length, at intervals of 400 feet (121,920 mm) maximum....
-
11B-903.4 Back support
Back support shall be 48 inches (1219 mm) long minimum and shall extend from a point 2 inches (51 mm) maximum above the seat surface to a point 18 inches (457 mm) minimum above the seat...
-
Re: Section 307 Protruding Objects
The (maximum) depth of a shelf isn't noted, but you're unlikely to find many shelves less than 4" deep....
-
§ 35.152(c)(2)
(2) Is integrated with other cells to the maximum extent feasible; and ...
-
§ 35.151(k)(2)(ii)
(ii) Is integrated with other cells to the maximum extent feasible;...
-
1009.3.2 Submerged Depth
Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (760 mm) maximum below the stationary water level....
-
602.2 Clear Floor Space
EXCEPTION: A parallel approach complying with 305 shall be permitted at units for children's use where the spout is 30 inches (760 mm) maximum above the finish floor or ground and is 3 1...
-
11B-403.7 Continuous gradient
All walks with continuous gradients shall have resting areas, 60 inches (1524 mm) in length, at intervals of 400 feet (121,920 mm) maximum....
-
R304.2.2 Running Slope
The running slope of the curb ramp shall be 5 percent minimum and 8.3 percent maximum but shall not require the ramp length to exceed 4.5 m (15.0 ft)....
-
903.4 Back Support
Back support shall be 42 inches (1065 mm) long minimum and shall extend from a point 2 inches (51 mm) maximum above the seat surface to a point 18 inches (455 mm) minimum above the seat...
-
11B-805.7 Built-in cabinets and work surfaces
Since there is no change to the wording of Section 11B-805.7, there is no reason to expect that OSHPD will change its interpretation....