Clear floor space in front of bathtubs shall be as shown in Fig. 33.
Search Results "Plumbing Element"
-
4.20.2 FLOOR SPACE
-
4.20.2 Floor Space
Clear floor space in front of bathtubs shall be as shown in Fig. 33.
-
4.20.6 SHOWER UNIT
A shower spray unit with a hose at least 60 in (1525 mm) long that can be used as a fixed shower head or as a hand-held shower shall be provided.
-
4.20.6 Shower Unit
A shower spray unit with a hose at least 60 in (1525 mm) long that can be used both as a fixed shower head and as a hand-held shower shall be provided.
-
4.21 Shower Stalls
-
Drinking Fountains and Water Coolers [4.15]
Drinking Fountains and Water Coolers [4.15] Drinking fountains and water coolers accessible to people who use wheelchairs may be too low for people with a limited ability to bend...
-
4.21.1* General
Accessible shower stalls shall comply with 4.21.
-
4.21.1* GENERAL
Accessible shower stalls shall comply with 4.21. For shower stalls in accessible dwelling units, see 4.34.5.5.
-
4.21.2 Size and Clearances
Except as specified in 9.1.2, shower stall size and clear floor space shall comply with Fig. 35(a) or (b). The shower stall in Fig. 35(a) shall be 36 in by 36 in (915 mm by 915 mm)....
-
4.21.2 SIZE AND CLEARANCES
Shower stall size and clear floor space shall comply with Fig. 35(a) or (b). The shower stall in Fig. 35(a) shall be 36 in by 36 in (915 mm by 915 mm). The shower stall in Fig. 35(b)...
-
4.21.5 Controls
Faucets and other controls complying with 4.27.4 shall be located as shown in Fig. 37. In shower stalls 36 in by 36 in (915 mm by 915 mm), all controls, faucets, and the shower unit...
-
4.21.5 CONTROLS
Faucets and other controls complying with 4.27.4 shall be located as shown in Fig. 37. In shower stalls 36 in by 36 in (915 mm by 915 mm), all controls, faucets, and the shower unit...
-
Water Closets [4.16]
Water Closets [4.16] Accessible water closets, including those located in stalls, must comply with the requirements in 4.16. Clear floor space requirements at a toilet not located...
-
4.22.4 Water Closets
If toilet stalls are provided, then at least one shall be a standard toilet stall complying with 4.17; where 6 or more stalls are provided, in addition to the stall complying with...
-
4.22.4 WATER CLOSETS
If toilet stalls are provided, then at least one shall comply with 4.17; its water closet shall comply with 4.16. If water closets are not in stalls, then at least one shall comply...
-
4.22.6 Lavatories and Mirrors
If lavatories and mirrors are provided, then at least one of each shall comply with 4.19.
-
4.22.6 LAVATORIES AND MIRRORS
If lavatories and mirrors are provided, then at least one of each shall comply with 4.19.
-
4.23.4 WATER CLOSETS
If toilet stalls are provided, then at least one shall comply with 4.17; its water closet shall comply with 4.16. If water closets are not in stalls, then at least one shall comply...
-
4.23.4 Water Closets
If toilet stalls are provided, then at least one shall be a standard toilet stall complying with 4.17; where 6 or more stalls are provided, in addition to the stall complying with...
-
4.23.6 LAVATORIES AND MIRRORS
If lavatories and mirrors are provided, then at least one of each shall comply with 4.19.
-
4.23.6 Lavatories and Mirrors
If lavatories and mirrors are provided, then at least one of each shall comply with 4.19.
-
4.23.8 Bathing and Shower Facilities
If tubs or showers are provided, then at least one accessible tub that complies with 4.20 or at least one accessible shower that complies with 4.21 shall be provided..
-
4.23.8 BATHING AND SHOWER FACILITIES
If tubs or showers are provided, then at least one accessible tub that complies with 4.20 or at least one accessible shower that complies with 4.21 shall be provided.
-
Urinals [4.18]
Urinals [4.18] Where urinals are provided, at least one must comply with 4.18.