6) Water fountains ADAAG: Where there is more than one fountain on a floor, 50% must be accessible to persons using wheelchairs. If there is only one drinking fountain on a floor,...
Search Results "Plumbing Element"
Commonly Searched Documents
-
6) Water fountains
-
11B-608 Shower compartments
[See subsections ...]
-
11B-608.1 General
Shower compartments shall comply with Section 11B-608. Advisory 11B-608.1 General. Shower stalls that are 60 inches (1525 mm) wide and have no curb may increase the usability of a...
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing...
-
11B-606 Lavatories and sinks
[See subsections ...]
-
11B-213.3.2 Water closets
Where water closets are provided, at least 5 percent but no fewer tan one shall comply with Section 11B-604. [2010 ADA Standards] 213.3.2 Water Closets. Where water closets are...
-
11B-608.2.1 Transfer type shower compartments
Transfer type shower compartments shall be 36 inches (914 mm) by 36 inches (914 mm) clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch...
-
11B-608.2 Size and clearances for shower compartments
Shower compartments shall have sizes and clearances complying with Section 11B-608.2.
-
Element
An architectural or mechanical component of a building, facility, space, or site.
-
ELEMENT
[DSA-AC] An architectural or mechanical component of a building, facility, space or site.
-
Height: ADA Standard Section 606.3
Section 606.3 covers the current ADA Standards for the height of lavatories and sinks.
-
11B-202.3.3 Alteration of single elements
If alterations of single elements, when considered together, amount to an alteration of a room or space in a building or facility, the entire room or space shall be made accessible....
-
Transfer Type Shower Compartments: ADA Standard Section 608.5.1
Section 608.5.1 covers the current ADA Standards for controls in transfer type shower compartments.
-
Alternate Roll-In Type Shower Compartments: ADA Standard Section 608.3.3
Section 608.3.3 covers the current ADA Standards for grab bars in alternate roll-in type shower compartments.
-
Clearance: ADA Standard Section 607.2
Section 607.2 covers the current ADA Standards for bathtub clearances.
-
Toilet Compartments: ADA Standard Section 213.3.1
Section 213.3.1 covers scoping requirements in the current ADA Standards for toilet compartments.
-
11B-607.2 Clearance
Clearance in front of bathtubs shall extend the length of the bathtub and shall be 48 inches (1219 mm) wide minimum for forward approach and 30 inches (762 mm) wide minimum for...
-
11B-608.3.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry. Grab bars shall not be provided...
-
11B-608.5.1 Transfer type shower compartments
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches...
-
11B-213.3.1 Toilet compartments
Where toilet compartments are provided, at least five percent of the toilet compartments, or five percent of the combination of toilet compartments and urinals, but no fewer than one...
-
213.3 Plumbing Fixtures and Accessories
213.3 Plumbing Fixtures and Accessories. Plumbing fixtures and accessories provided in a toilet room or bathing room required to comply with 213.2 shall comply with 213.3....
-
11B-213.3 Plumbing fixtures and accessories
Plumbing fixtures and accessories provided in a toilet room or bathing room required to comply with Section 11B-213.2 shall comply with Section 11B-213.3. ...
-
11B-213.3 Plumbing fixtures and accessories
Plumbing fixtures and accessories provided in a toilet room or bathing room required to comply with Section 11B-213.2 shall comply with Section 11B-213.3. ...
-
11B-213.3 Plumbing fixtures and accessories
Plumbing fixtures and accessories provided in a toilet room or bathing room required to comply with Section 11B-213.2 shall comply with Section 11B-213.3....