Clearance in front of bathtubs shall extend the length of the bathtub and shall be 48 inches (1219 mm) wide minimum for forward approach and 30 inches (762 mm) wide minimum for...
Search Results "Plumbing Element"
-
11B-607.2 Clearance
-
11B-608.5.1 Transfer type shower compartments
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches...
-
11B-608.3.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry. Grab bars shall not be provided...
-
11B-607.2 Clearance
Clearance in front of bathtubs shall extend the length of the bathtub and shall be 48 inches (1219 mm) wide minimum for forward approach and 30 inches (762 mm) wide minimum for...
-
11B-608.5.1 Transfer type shower compartments
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches...
-
11B-608.3.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry. Grab bars shall not be provided...
-
213.3 Plumbing Fixtures and Accessories
213.3 Plumbing Fixtures and Accessories. Plumbing fixtures and accessories provided in a toilet room or bathing room required to comply with 213.2 shall comply with 213.3....
-
11B-213.3 Plumbing fixtures and accessories
Plumbing fixtures and accessories provided in a toilet room or bathing room required to comply with Section 11B-213.2 shall comply with Section 11B-213.3. ...
-
11B-213.3 Plumbing fixtures and accessories
Plumbing fixtures and accessories provided in a toilet room or bathing room required to comply with Section 11B-213.2 shall comply with Section 11B-213.3. ...
-
11B-213.3 Plumbing fixtures and accessories
Plumbing fixtures and accessories provided in a toilet room or bathing room required to comply with Section 11B-213.2 shall comply with Section 11B-213.3....
-
F213.3 Plumbing Fixtures and Accessories
Plumbing fixtures and accessories provided in a toilet room or bathing room required to comply with F213.2 shall comply with F213.3....
-
213.3 Plumbing Fixtures and Accessories
Plumbing fixtures and accessories provided in a toilet room or bathing room required to comply with 213.2 shall comply with 213.3....
-
11B-213.3.2 Water closets
Where water closets are provided, at least five percent but no fewer than one shall comply with Section 11B-604. ETA Editor's Note The 2013 CBC scoping for accessible water...
-
11B-608.2.3 Alternate roll-in type shower compartments
Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
608.2.3 Alternate Roll-In Type Shower Compartments
Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
Alternate Roll-in Showers
Comment. Specifications are provided for alternate roll-in showers, including their size and the location of entries (608.2.3). Comments indicated that this provision should be more...
-
608.2.3 Alternate Roll-In Type Shower Compartments
Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
608.2.3 Alternate Roll-In Type Shower Compartments
608.2.3 Alternate Roll-In Type Shower Compartments. Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside...
-
4.24.2 Height
Sinks shall be mounted with the counter or rim no higher than 34 in (865 mm) above the finish floor.
-
Bathrooms
Bathrooms An accessible bathroom can be equipped with either a tub or shower (transfer or roll-in).
-
4.24.4 Depth
Each sink shall be a maximum of 6‒1/2 in (165 mm) deep.
-
F212.3 Sinks
The final rule adds Exception 2 to this section, which contains the scoping requirements for sinks. Exception 2 exempts sinks in camping facilities and picnic facilities where a...
-
4.24.4 DEPTH
Each sink shall be a maximum of 6-1/2 in (165 mm) deep.
-
4.24.2 HEIGHT
Sinks shall be mounted with the counter or rim no higher than 34 in (865 mm) from the floor.