Compartments containing more than one plumbing fixture shall comply with 603. Ambulatory accessible compartments shall comply with 604.8.2 and 604.8.3....
Search Results "Plumbing Element"
-
604.8 Toilet Compartments
-
604.8 Toilet Compartments
Compartments containing more than one plumbing fixture shall comply with 603. Ambulatory accessible compartments shall comply with 604.8.2 and 604.8.3....
-
11B-604.8 Toilet compartments
Compartments containing more than one plumbing fixture shall comply with Section 11B-603. Ambulatory accessible compartments shall comply with Sections 11B-604.8.2 and 11B-604.8.3....
-
Toilet and Bathing Facilities: ADA Standard Section 806.2.4
At least one bathroom that is provided as part of a guest room shall comply with 603. No fewer than one water closet, one lavatory, and one bathtub or shower shall comply with...
-
11B-224.2 Guest rooms with mobility features
In transient lodging facilities, guest rooms with mobility features complying with Section 11B-806.2 shall be provided in accordance with Table 11B-224.2, as follows. [2010 ADA...
-
11B-806.2.4 Toilet and bathing facilities
At least one bathroom that is provided as part of a guest room shall comply with Section 11B-603. No fewer than one water closet, one lavatory, and one bathtub or shower shall comply...
-
11B-224.2 Guest rooms with mobility features
In transient lodging facilities and housing at a place of education, guest rooms with mobility features complying with Section 11B-806.2 shall be provided in accordance with Table...
-
11B-806.2.4 Toilet and bathing facilities
At least one bathroom that is provided as part of a guest room shall comply with Section 11B-603. No fewer than one water closet, one lavatory, and one bathtub or shower shall comply...
-
3. Element-by-Element Safe Harbor
Element-by-Element Safe Harbor....
-
3. Element by Element Safe Harbor
Element by Element Safe Harbor....
-
Plumbed Fixtures
Plumbed Fixtures ADAAG covers fixed units where they are provided. Fixed units are not required over units that are not fixed....
-
Element
Element. An architectural or mechanical component of a building, facility, space, or site....
-
ELEMENT
ELEMENT. [DSA-AC] An architectural or mechanical component of a building, facility, space or site....
-
Element
Element. An architectural or mechanical component of a building, facility, space, site, or public right-of-way....
-
11B-805.2.1 Hand washing fixtures
Hand washing fixtures shall comply with Section 11B-606.
-
Sinks [F212.3, Exception 2]
Sinks in camping and picnic facilities are not required to comply with the technical requirements for sinks in Section 606 of the ABA Standards, unless a cooktop or conventional...
-
11B-213.3.1 Toilet compartments
SECTION TITLE NOTES 11B-213.3.1 Toilet compartments Corrects drafting...
-
604.8.1.6 Lavatory
604.8.1.6 Lavatory. In new construction, the wheelchair accessible toilet compartment shall contain an accessible lavatory within it, which must be at least 19 inches wide by 17...
-
4.20.2 Floor Space
Clear floor space in front of bathtubs shall be as shown in Fig. 33.
-
A4.21.1 General
Shower stalls that are 36 in by 36 in (915 mm by 915 mm) wide provide additional safety to people who have difficulty maintaining balance because all grab bars and walls are within...
-
Size and Clearances [4.21.2]
Size and Clearances [4.21.2] Lavatories can be located within the clear floor space (as shown in ADAAG Figure 35). Recommendation:Placing them beyond this space however can...
-
4.23.8 Bathing and Shower Facilities
If tubs or showers are provided, then at least one accessible tub that complies with 4.20 or at least one accessible shower that complies with 4.21 shall be provided..
-
604 Water Closets and Toilet Compartments
(This section is to be used for toilet buildings with multiple risers provided at recreation sites with a FS Recreation Site Development Scale of 3 or higher, and for the Exception...
-
4.7.9.4 Depth
The bottom of the bowl shall be at least 15 inches (380 mm) above the floor or ground.