(5) Each bedroom shall have a door that complies with 4.13....
Search Results "Door Maneuvering Clearance"
Commonly Searched Documents
-
6.3(5)
-
End-of-Row Stalls
End-of-Row Stalls The design of end-of-row stalls incorporates aisle space into the stall for easier maneuvering; consider this design even where a stall is not located at the end of...
-
4.8.4(4)
(4) If a doorway is located at a landing, then the area in front of the doorway shall comply with 4.13.6.
-
4.13.4 Double-Leaf Doorways
If doorways have two independently operated door leaves, then at least one leaf shall meet the specifications in 4.13.5 and 4.13.6. That leaf shall be an active leaf....
-
4.13.4 DOUBLE-LEAF DOORWAYS
If doorways have two independently operated door leaves, then at least one leaf shall meet the specifications in 4.13.5 and 4.13.6. That leaf shall be an active leaf....
-
Doors [4.35.3]
Doors [4.35.3] The size of rooms is further determined by the location and swing of doors....
- Figure 404.2.4.2(a) Maneuvering Clearances at Doorways without Doors, Sliding Doors, Gates, and Folding Doors – Drawing from the U.S. Access Board
- SafePath: ADA Door Access - What is a Level Landing?
-
Door Delay: ADA Standard Section 407.3.5
Section 407.3.5 covers the current ADA Standards for elevator door delay.
- Figure 404.2.4.2(b) Maneuvering Clearances at Doorways without Doors, Sliding Doors, Gates, and Folding Doors – Drawing from the U.S. Access Board
- Figure 404.2.4.2(d) Maneuvering Clearances at Doorways without Doors, Sliding Doors, Gates, and Folding Doors – Drawing from the U.S. Access Board
- Figure 404.2.4.2(c) Maneuvering Clearances at Doorways without Doors, Sliding Doors, Gates, and Folding Doors – Drawing from the U.S. Access Board
-
4.8.4* Landings
Ramps shall have level landings at bottom and top of each ramp and each ramp run. Landings shall have the following features:
-
4.8.4 LANDINGS
Ramps shall have level landings at the bottom and top of each run. Landings shall have the following features: (1) The landing shall be at least as wide as the ramp run leading to...
- Figure 404.2.4.1(k) Maneuvering Clearances at Manual Swinging Doors and Gates: Latch Approach, Push Side with Closer – Drawing from the U.S. Access Board
-
1132A.4 Level floor or landing
The floor or landing on each side of a door shall be level....
-
1010.1.5 Floor elevation
There shall be a floor or landing on each side of a door. Such floor or landing shall be at the same elevation on each side of the door....
-
11B-404.2.4.4 Floor or ground surface
Floor or ground surface within required maneuvering clearances shall comply with Section 11B-302....
-
1132A.4 Level floor or landing
The floor or landing on each side of a door shall be level....
-
General: ADA Standard Section 404.1
Section 404.1 of the ADA Standards covers information in the current ADA Standards for doors, doorways, and gates that are part of an accessible route.
-
1132A.4 Level floor or landing
The floor or landing on each side of a door shall be level....
-
D4
On the latch, pull side of the door, is there at least 18 inches clearance provided if the door is not automatic or power-operated?...
-
Door and Gate Opening Force: ADA Standard Section 404.2.9
Section 404.2.9 covers the current ADA Standards for door and gate opening force.
-
A4.17.5 Doors
To make it easier for wheelchair users to close toilet stall doors, doors can be provided with closers, spring hinges, or a pull bar mounted on the inside surface of the door near the hinge...