Clearances at power-assisted doors and gates shall comply with 404.2.4....
Search Results "Door Maneuvering Clearance"
Commonly Searched Documents
-
404.3.2 Maneuvering Clearance
-
Recessed Doors and Gates [§404.2.4.3]
Recessed Doors and Gates [§404.2.4.3] Thick walls, casework, shelving, columns and other elements can cause doors or gates to be recessed....
-
Doorways [4.8.4]
Landings must provide the maneuvering clearance at doors required in ADAAG 4.13. ADAAG allows the landing to overlap maneuvering clearances at doors....
-
Is additional latch side clearance required on the push side of doors with a forward approach when either a latch or closer (but not both) is provided?
No, latch clearance 12” minimum is required for forward approaches on the push-side of doors equipped with both a closer and a latch....
-
Inventory Control Devices
Inventory Control Devices It is important that inventory control or security devices not obstruct required maneuvering clearances at doors....
-
Entry Doors
Entry Doors Under the ADA Standards for Accessible Design, an accessible doorway must have a minimum clear opening width of 32 inches when the door is opened to 90 degrees....
-
11B-404.2.4.1 Swinging doors and gates
Swinging doors and gates shall have maneuvering clearances complying with Table 11B-404.2.4.1....
-
11B-404.2.4.1 Swinging doors and gates
Swinging doors and gates shall have maneuvering clearances complying with Table 11B-404.2.4.1....
-
A. Slope at Door
If a fully automatic door is not provided, is the walkway in front of the lobby door level, without any portion steeper than 1:50 (critical dimension of ´" or less), so persons who use wheelchairs...
-
1132A.5.2 Strike edge maneuvering space at doors
The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors....
-
1132A.5.2 Strike edge maneuvering space at doors
The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors....
-
305.7 Maneuvering Clearance
Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance shall be provided in accordance with 305.7.1...
-
11B-305.7 Maneuvering clearance
Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance shall be provided in accordance with Sections...
-
C. Doors
Doors - Examine each of the interior routes described above: ...with the exception of doors at shallow closets, do the doors to required accessible spaces, and all doors into and within...
- SafePath EntryLevel™ Landings
-
11B-809.10.4 Sufficient maneuvering space
Where doors swing into the toilet and bathing or powder rooms required to comply with Section 11B-809.10, a clear maneuvering space of 30 (762 mm) inches by 48 inches (1219 mm) minimum shall...
-
Doorways at Landings [§405.7.5]
Doorways at Landings [§405.7.5] Required door maneuvering clearances can overlap ramp landings (it is advisable to locate the swing of doors outside ramp landings for greater safety)....
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide...
-
Is compliance on both sides of a door or gate required when it is usable only from one side?
No, compliance is not required on both sides of those doors or gates that can be used in one direction only. Compliance is required only on the usable side....
-
409.3 Elevator Doors
Hoistway doors, car doors, and car gates shall comply with 409.3 and 404....
-
409.3 Elevator Doors
Hoistway doors, car doors, and car gates shall comply with 409.3 and 404....
-
409.3 Elevator Doors
409.3 Elevator Doors. Hoistway doors, car doors, and car gates shall comply with 409.3 and 404....
-
California/ADA Plan Review Tool - Door Maneuvering Clearances
California/ADA Plan Review Tool - Door Maneuvering Clearances Click here to view/download the pdf "California/ADA Plan Review Tool - Door Maneuvering Clearances" (250 KB) * * * * *...
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...