On the pull side of each door (i.e.: entry door, connecting room door, bathroom doors and other passage doors) in every accessible guestroom/suite, are there at least 18" of clear floor...
Search Results "Door Maneuvering Clearance"
-
H. Door Maneuvering Clearance
-
11. Door Maneuvering Clearance
Is there adequate room for a person who uses a wheelchair to approach the bathroom door in each accessible guestroom bathroom from the pull side and pull it open without it hitting the wheelchair...
-
Attachment A: Violations Identified in the United States' Letter of Findings (Sept. 29, 2014)
-
Polling places that cannot be remediated with temporary measures:
Building Entrance & Voting Area: The door at the designated accessible entrance does not provide at least 32 inches clear passage width when the door is open 90 degrees (1991 ADA Stds...
-
Door Maneuvering Clearance
Table 404.2.4.1 specifies maneuvering clearances for manual swinging doors and gates....
-
Door Maneuvering Clearance
Section 404.2.4 addresses maneuvering clearances at manual doors, doorways, and gates....
-
H4
On the pull side of the door, is there at least 18 inches clearance provided on the latch side if the door is not automatic or power-operated?...
-
Doors
Doors: a. Main Lobby restroom: provide a restroom vestibule door with at least 18" of maneuvering clearance on the latch side of the door. See Standards § 4.13.6....
-
404.1 General
Doors, doorways, and gates that are part of an accessible route shall comply with 404....
-
404.2.4 Maneuvering Clearances
Minimum maneuvering clearances at doors and gates shall comply with 404.2.4....
-
404.2.4.1 Swinging Doors and Gates
Swinging doors and gates shall have maneuvering clearances complying with Table 404.2.4.1....
-
404.2.4.2 Doorways without Doors or Gates, Sliding Doors, and Folding Doors
Doorways less than 36 inches (915 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 404.2.4.2....
-
404.2.4.3 Recessed Doors and Gates
Maneuvering clearances for forward approach shall be provided when any obstruction within 18 inches (455 mm) of the latch side of a doorway projects more than 8 inches (205 mm) beyond the...
-
404.2.4.4 Floor or Ground Surface
Floor or ground surface within required maneuvering clearances shall comply with 302. Changes in level are not permitted. EXCEPTIONS: 1....
-
404.3.2 Maneuvering Clearance
Clearances at power-assisted doors and gates shall comply with 404.2.4....
-
405.7.5 Doorways
Where doorways are located adjacent to a ramp landing, maneuvering clearances required by 404.2.4 and 404.3.2 shall be permitted to overlap the required landing area....
-
409.3 Elevator Doors
Hoistway doors, car doors, and car gates shall comply with 409.3 and 404....
-
Entrance Landings
Entrance landings must accommodate door maneuvering clearances as well as landings for provided ramps. Entrance Landing...
-
Manual Doors and Gates [§404.2]
Manual Doors and Gates [§404.2]...
-
Maneuvering Clearances [§404.2.4]
Maneuvering Clearances [§404.2.4] Required maneuvering clearances provide space for opening and proceeding through doors, doorways, and gates using wheelchairs and other mobility aids...
-
Recessed Doors and Gates [§404.2.4.3]
Recessed Doors and Gates [§404.2.4.3] Thick walls, casework, shelving, columns and other elements can cause doors or gates to be recessed....
-
Power-Assisted Doors and Gates [§404.3]
Power-Assisted Doors and Gates [§404.3] Power-assisted devices reduce the opening force of doors with closing mechanisms....