Toilet stall doors, including door hardware, shall comply with 4.13....
Search Results "Door Maneuvering Clearance"
-
4.17.5* Doors
-
Maneuvering Clearances at Doors [4.13.6]
Maneuvering Clearances at Doors [4.13.6] Pull-side clearance beyond the door swing provides space for a forward reach to door hardware....
-
Clearances for Side Approaches
Clearances for Side Approaches Clearance for side approaches are based on the swing of doors, direction of approach (hinge or latch), and the provision of closers (in some cases latches...
-
End-of-Row Stalls
End-of-Row Stalls The design of end-of-row stalls incorporates aisle space into the stall for easier maneuvering; consider this design even where a stall is not located at the end of...
-
Single-User Toilet Rooms: Side Transfer Space
Doors must comply with 4.13, which specifies maneuvering clearances. The location of doors is based on their size and sweep....
-
Doors [4.35.3]
Doors [4.35.3] The size of rooms is further determined by the location and swing of doors....
-
Doors
Doors The exception from latch-side maneuvering clearances is allowed only at acute care bedrooms, not throughout a hospital....
-
Inventory Control Devices
Inventory Control Devices It is important that inventory control or security devices not obstruct required maneuvering clearances at doors....
-
Can handrails overlap door maneuvering clearances?
No, door maneuvering clearances must be free of any overlapping objects, even those providing knee and toe clearance, which can interfere with maneuvering at doors and doorways....
-
404.1 General
Doors, doorways, and gates that are part of an accessible route shall comply with 404....
-
404.2.4 Maneuvering Clearances
Minimum maneuvering clearances at doors and gates shall comply with 404.2.4....
-
404.2.4.1 Swinging Doors and Gates
Swinging doors and gates shall have maneuvering clearances complying with Table 404.2.4.1....
-
404.2.4.2 Doorways without Doors or Gates
Doorways less than 36 inches (915 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 404.2.4.2....
-
404.2.4.3 Recessed Doors and Gates
Maneuvering clearances for forward approach shall be provided when any obstruction within 18 inches (455 mm) of the latch side of a doorway projects more than 8 inches (205 mm) beyond the...
-
404.2.4.4 Floor or Ground Surface
Floor or ground surface within required maneuvering clearances shall comply with 302. Changes in level are not permitted. EXCEPTIONS: 1....
-
404.3.2 Maneuvering Clearance
Clearances at power-assisted doors and gates shall comply with 404.2.4....
-
405.7.5 Doorways
Where doorways are located adjacent to a ramp landing, maneuvering clearances required by 404.2.4 and 404.3.2 shall be permitted to overlap the required landing area....
-
Door stop
-
409.3 Elevator Doors
Hoistway doors, car doors, and car gates shall comply with 409.3 and 404....
-
Question 10
Is the accessible entrance into the building free of obstacles that block the clear wall and floor space needed for opening the door (between 18 and 42 inches on the latch side of the door...
-
Question 19
Are the entrances to accessible public restrooms and fitting rooms free of obstacles that block the clear wall and floor space needed for opening the door (between 18 and 42 inches on the...
-
Error/Omission: Adequate maneuvering clearance is not provided at doors, including doors to accessible toilet stalls.
Error/Omission: Adequate maneuvering clearance is not provided at doors, including doors to accessible toilet stalls....
-
6.3(1)
(1) Each bedroom shall have a door that complies with 4.13....
-
1010.1.5 Floor elevation
There shall be a floor or landing on each side of a door. Such floor or landing shall be at the same elevation on each side of the door....