Unoccupied Device Length The research data shows that the sizes of devices vary considerably from the values in the standards....
Search Results "Counter Length"
-
4.1 Wheeled Mobility Device Dimensions
-
606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (865 mm) maximum above the finish floor or ground. EXCEPTIONS: 1....
-
Table 1
the requirements in the DOJ 2010 Standards because the requirements are the same. 24The requirements analyzed in Table 1 include: drinking fountains, public toilet facilities, tables, counters...
-
Do access aisle borders (in blue) have to be painted on all four sides to be considered compliant?
I would also say that both of the "end" lines would/could be within the required length. ...
-
Handrail extension requirements
Most concise demonstration of how to (correctly) measure handrail extension length I've come across. No more arguing with Architects...will just send them this link....
-
Plan 3B: 12-Foot Wide Accessible Guest Room
The following accessible features are provided in the bathroom: • Comparable vanity counter top space (section 806); • Standard roll-in type shower with folding seat (section 608.2.2...
-
407.8.2 Side Reach
The vertical reference plane shall be centered on the operable part and placed at the leading edge of the maximum protrusion of the ICT within the length of the vertical reference plane....
-
407.12.2 Side Reach
The vertical reference plane shall be centered on the operable part and placed at the leading edge of the maximum protrusion of the ICT within the length of the vertical reference plane....
-
Cross Slope
Cross Slope—The percentage of rise to length when measuring the trail tread from edge to edge perpendicular to the direction of travel....
-
Digital inclinometers (SmartTool®)
They have an accuracy of 0.1 degree and come in 2 - foot and 4 - foot lengths....
- ACCESSMAT® - EN - Beach accessibility mats
-
Accessible Boat Slips
There are three exceptions: The width of the clear pier space may be 36 inches wide for a length of 24 inches, as long as multiple 36-inch segments are separated by segments...
-
R305.2.4 Pedestrian Refuge Islands
At cut-through pedestrian refuge islands, detectable warning surfaces shall be placed at the edges of the pedestrian island and shall be separated by a 610 mm (2.0 ft) minimum length of...
-
f-v
If a ramp is more than 30 feet long, is a level landing at least 60 inches long provided at every 30 feet of horizontal length?...
-
4d.
If a ramp is more than 30 feet long, is a level landing at least 60 inches long provided every 30 feet of horizontal length?...
-
7.4.5 Passing Spaces
A passing space must also be provided at the end of any segment of trail that meets the requirements of 7.4, if the full length of the trail does not meet the requirements. ...
-
1017.10 Trailhead Signs
This section requires trail information signs at trailheads to include information on the length of the trail or trail segment; surface type; typical and minimum tread width; typical and...
-
604.5 Grab Bars
Reinforcement must be sufficient to permit the installation of rear and side wall grab bars that fully meet all accessibility requirements including, but not limited to, required length,...
-
§382.145(a)
instructional materials provided for the carrier and contract personnel who provide services to passengers, including, but not limited to, pilots, flight attendants, reservation and ticket counter...
-
Comments on specific provisions of proposed ADAAG (Preamble, Section-by-Section Analysis)
Strenuous objections were raised by some business commenters to the proposed provisions of the guidelines concerning check-out aisles, counters, and scoping for hotels and nursing facilities...
-
382.57 What services must carriers provide if their automated kiosks are inaccessible?
For example, a passenger who cannot use the kiosk could be allowed to come to the front of the line at the check-in counter, or carrier personnel could meet the passenger at the kiosk and...
-
606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (865 mm) maximum above the finish floor or ground. EXCEPTIONS: 1....
-
Height [4.27.3]
This is important where controls and switches are mounted on walls above counters....
-
Accessible Routes: ADA Standard Section 1007.2
Ramp landing length specified by 405.7.3 shall be permitted to be 48 inches (1220 mm) long minimum. 6....