Handset cords, if provided, shall be 29 inches (737 mm) long minimum....
Search Results "Minimum Dimension"
-
11B-708.3 Handsets
-
11B-411.2.1.2.4.2 Size
Elevator assignment characters shall be 1 inch high (25 mm) minimum....
-
Height Above Finish Floor or Ground: ADA Standard Section 703.4.1
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches...
-
Parallel Approach: ADA Standard Section 904.4.1
A portion of the counter surface that is 36 inches (915 mm) long minimum and 36 inches (915 mm) high maximum above the finish floor shall be provided....
-
Visible Signals: ADA Standard Section 407.2.2.2
Section 407.2.2.2 covers the current ADA Standards for elevator visible signals.
-
Location: ADA Standard Section 604.9.1
Section 604.9.1 covers the current ADA Standards for the mounting location of children's use water closets.
-
11B-804.3 Kitchen work surface
In residential dwelling units required to comply with Section 11B-809, at least one 30 inches (762 mm) wide minimum section of counter shall provide a kitchen work surface that complies...
-
11B-604.9.1 Location
The centerline of the water closet shall be 12 inches (305 mm) minimum and 18 inches (457 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (432...
-
11B-804.3 Kitchen work surface
In residential dwelling units required to comply with Section 11B-809, at least one 30 inches (762 mm) wide minimum section of counter shall provide a kitchen work surface that complies...
-
11B-604.9.1 Location
The centerline of the water closet shall be 12 inches (305 mm) minimum and 18 inches (457 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (432...
- Bobrick MatrixSeries Seat-Cover Dispenser B-5221
-
11B-805.6 Hand washing fixtures, lavatories and sinks
above the finish floor or ground at a depth of 8 inches (203 mm) minimum increasing to 29 inches (737 mm) high minimum above the finish floor or ground at the front edge of a counter with...
-
11B-805.6 Hand washing fixtures, lavatories and sinks
above the finish floor or ground at a depth of 8 inches (203 mm) minimum increasing to 29 inches (737 mm) high minimum above the finish floor or ground at the front edge of a counter with...
-
This is a great unit but it's not "recessed", it's semi-recessed.
If you place this unit next to the accessible lavatory or other required clear space and don't allow room for the projection, it may interfere with the minimum required clear floor space...
-
Clear Width: ADA Standard Section 404.2.3
Section 404.2.3 covers the current ADA Standards for clear width at manual doors, doorways and manual gates that are part of an accessible route.
-
11B-404.2.3 Clear width
Door openings shall provide a clear width of 32 inches (813 mm) minimum....
-
11B-404.2.3 Clear width
Door openings shall provide a clear width of 32 inches (813 mm) minimum....
-
Cord Length: ADA Standard Section 704.2.4
The cord from the telephone to the handset shall be 29 inches (735 mm) long minimum....
-
Depth: ADA Standard Section 703.2.1
Raised characters shall be 1/32 inch (0.8 mm) minimum above their background....
-
Frequency: ADA Standard Section 407.4.8.2.3
Section 407.4.8.2.3 covers the current ADA Standards for the frequency of audible elevator car indicators.
-
Clear Width: ADA Standard Section 1006.3.1
The clear width of golf car passages shall be 48 inches (1220 mm) minimum....
-
11B-703.2.1 Depth
Raised characters shall be 1/32 inch (0.8 mm) minimum above their background....
-
11B-704.2.4 Cord length
The cord from the telephone to the handset shall be 29 inches (737 mm) long minimum....
-
11B-812.8.6 Finish and size
Identification signs shall be reflectorized with a minimum area of 70 square inches (45161 mm2)....