The clear width of a ramp run shall be 48 inches (1219 mm) minimum....
Search Results "Minimum Dimension"
Commonly Searched Documents
-
11B-405.5 Clear width
-
11B-223.1.1 Alterations
Section 11B-223 shall apply only to the patient bedrooms or resident sleeping rooms being altered or added until the number of patient bedrooms or resident sleeping rooms complies with the minimum...
-
Back Support: ADA Standard Section 903.4
Back support shall be 42 inches (1065 mm) long minimum and shall extend from a point 2 inches (51 mm) maximum above the seat surface to a point 18 inches (455 mm) minimum above the seat...
-
Golf Club Reach Range Area: ADA Standard Section 1007.3.2
All areas within holes where golf balls rest shall be within 36 inches (915 mm) maximum of a clear floor or ground space 36 inches (915 mm) wide minimum and 48 inches (1220 mm) long minimum...
-
Seats: ADA Standard Section 604.4
Section 604.4 covers the current ADA Standards for the water closet seats.
-
11B-223.1.1.2 Individual alterations
patient bedrooms or resident sleeping rooms provided in the department or area containing the individually altered or added patient bedrooms or resident sleeping rooms complies with the minimum...
-
11B-407.2.2.3 Audible signals
Verbal annunciators shall have a frequency of 300 Hz minimum and 3000 Hz maximum....
-
11B-1007.3.2 Golf club reach range area
All areas within holes where golf balls rest shall be within 36 inches (914 mm) maximum of a clear floor or ground space 36 inches (914 mm) wide minimum and 48 inches (1219 mm) long minimum...
-
11B-809.10.5.4 Bathtub enclosures
When glass is used, it shall be 1/8 inch (3.2 mm) thick minimum when fully tempered, or 1/4 inch (6.4 mm) thick minimum when laminated, and shall pass the test requirements of this part,...
-
11B-1009.2.9 Lifting capacity
Single person pool lifts shall have a weight capacity of 300 pounds (136 kg) minimum and be capable of sustaining a static load of at least one and a half times the rated load....
-
Ambulatory Accessible Compartment
Throughout the new guidelines, the Board has sought to specify dimensions as a range instead of in absolute terms where practicable to facilitate compliance without compromising accessibility...
-
5.3.2.1 Transfer Sides Recommendation for Stretchers
5.3.2.1 Transfer Sides Recommendation for Stretchers On stretchers, the transfer surface is oriented along the long dimension of the surface on which patients are in the supine, prone...
-
9. Exterior Ramps
[ADA Stds. 4.8.3] Yes __ No __ N/A __ Comments: _______________________________ d. do the exterior ramps have running slopes that are 1:12 or less (critical dimension of 2" or less...
-
4.4.4 Clear Floor or Ground Space
The long dimension of the clear space shall be roughly perpendicular to the length of the bench....
-
Department of Justice method
Use the tape measure and measure the open gap at the downhill end of the level to establish the critical dimension....
-
Control End Wall: ADA Standard Section 607.4.2.2
Section 607.4.2.2 covers the current ADA Standards for grab bars on the control end of bathtubs without permanent seats.
-
Head End Wall: ADA Standard Section 607.4.2.3
Section 607.4.2.3 covers the current ADA Standards for grab bars on the head end wall of bathtubs without permanent seats.
-
Pictogram Field: ADA Standard Section 703.6.1
Pictograms shall have a field height of 6 inches (150 mm) minimum. Characters and braille shall not be located in the pictogram field....
-
Control End Wall: ADA Standard Section 607.4.1.2
Section 607.4.1.2 covers the current ADA Standards for grab bars on the control end of bathtubs with permanent seats.
-
11B-607.4.2.3 Head end wall
A grab bar 12 inches (305 mm) long minimum shall be installed on the head end wall at the front edge of the bathtub. ...
-
11B-607.4.1.2 Control end wall
A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub....
-
11B-607.4.2.2 Control end wall
A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub....
- U.N. Convention on the Rights of Persons with Disabilities (CRPD)
-
M301.4.1 Clearance in Base (Section-by-Section Analysis)
The MDE NPRM proposed a clearance in the base of 44 inches wide minimum, 6 inches high minimum measured from the floor, and 36 inches deep minimum measured from the edge of the examination...