Curbs or barriers shall extend 2 inches (51 mm) minimum above the surface of the fishing pier or platform....
Search Results "Minimum Dimension"
-
11B-1005.3.1 Curb or barrier
-
11B-503.3.1 Width
Access aisles serving vehicle pull-up spaces shall be 60 inches (1524 mm) wide minimum....
-
11B-502.3.1 Width
Access aisles serving car and van parking spaces shall be 60 inches (1524 mm) wide minimum....
-
11B-407.4.8.2.2 Signal level
The verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the annunciator....
-
11B-407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (889 mm) minimum above the finish floor....
-
11B-409.4.6.2 Location
Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall....
-
Stroke Thickness: ADA Standard Section 703.5.7
Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 30 percent maximum of the height of the character....
-
11B-411.4.11.1 Height
Floor destination characters shall be 1 inch (25 mm) high minimum complying with Section 11B-703.5.3....
-
11B-407.4.8.2.2 Signal level
The verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the annunciator....
-
11B-411.4.11.1 Height
Floor destination characters shall be 1 inch (25 mm) high minimum complying with Section 11B-703.5.3....
-
Preliminary Guidelines for SEWF Installation
Compact and smooth the surface by using a large trowel or stiff plywood (16 mm or 5/8 in.) of dimension 1.2 by 1.2 m (4 by 4 ft) covered with a heavy-mil sheet of polyethylene as a release...
-
Section 1.0 Background
It is likely that the current U.S. standards do not reflect the actual dimensions and abilities of contemporary WhMD users....
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
11B-809.10.6.3 Clearance
A clearance of 36 inches (914 mm) wide minimum by 48 inches (1219 mm) long minimum measured from the control wall shall be provided outside the shower as illustrated in Figure 11B-809.10.6.3...
-
Lifting Capacity: ADA Standard Section 1009.2.9
Single person pool lifts shall have a weight capacity of 300 pounds. (136 kg) minimum and be capable of sustaining a static load of at least one and a half times the rated load....
-
Station 5-Lateral Operating Space (Sweep Width)
Space requirements of transportation users are one of the essential inputs in facility design, particularly in determining cross-sectional dimension needs of facilities....
-
11B-305.7.1 Forward approach
Alcoves shall be 36 inches (914 mm) wide minimum where the depth exceeds 24 inches (610 mm)....
-
11B-305.7.2 Parallel approach
Alcoves shall be 60 inches (1524 mm) wide minimum where the depth exceeds 15 inches (381 mm)....
-
Forward Approach: ADA Standard Section 305.7.1
Section 305.7.1 covers the current ADA Standards for the clear floor or ground space required for forward approach.
-
Parallel Approach: ADA Standard Section 305.7.2
Section 305.7.2 covers the current ADA Standards for the clear floor or ground space required for parallel approach.
-
Faucets: ADA Standard Section 606.4
Section 606.4 covers the current ADA Standards for the faucet controls of lavatories and sinks.
-
11B-305.7.2 Parallel approach
Alcoves shall be 60 inches (1524 mm) wide minimum where the depth exceeds 15 inches (381 mm)....
-
11B-305.7.1 Forward approach
Alcoves shall be 36 inches (914 mm) wide minimum where the depth exceeds 24 inches (610 mm)....