Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (864 mm) maximum above the finish floor or ground....
Search Results "Maximum Dimension"
-
11B-606.3 Height
-
11B-606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (864 mm) maximum above the finish floor or ground....
-
11B-809.12 Electrical receptacles, controls and switches
branch circuits of 30 amperes or less, communication system receptacles, controls and switches shall be located as follows: Where there is no obstruction, 48 inches (1219 mm) maximum...
-
11B-809.12 Electrical receptacles, controls and switches
branch circuits of 30 amperes or less, communication system receptacles, controls and switches shall be located as follows: Where there is no obstruction, 48 inches (1219 mm) maximum...
-
1008.3.1.3 Transfer Space
The 48 inch (1220 mm) long minimum dimension of the transfer space shall be centered on and parallel to the 24 inch (610 mm) long minimum side of the transfer platform....
-
11B-1008.3.1.3 Transfer space
The 48 inch (1219 mm) long minimum dimension of the transfer space shall be centered on and parallel to the 24 inch (610 mm) long minimum side of the transfer platform....
-
A. Slope at Door
If a fully automatic door is not provided, is the walkway in front of the lobby door level, without any portion steeper than 1:50 (critical dimension of ´" or less), so persons who use wheelchairs...
-
407.12.1.1 Vertical Plane for Side Reach (Section-by-Section Analysis)
The 48-inch dimension is based on the length of a stationary occupied wheelchair. This side reach requirement mirrors existing 508 Standards § 1194.25(j)(1) and Figure 1....
-
R305.2 Placement
Where the back of curb edge is tooled to provide a radius, the border dimension should be measured from the end of the radius....
-
R103.2 Calculation of Percentages
Where the determination of the required size or dimension of an element or facility involves ratios or percentages, rounding down for values less than one half is permitted....
-
Controls [4.21.5]
The dimensions for seats in 36 inch stalls are appropriate for seats in roll-in showers as well....
-
11B-1008.3.1.3 Transfer space
The 48 inch (1219 mm) long minimum dimension of the transfer space shall be centered on and parallel to the 24 inch (610 mm) long minimum side of the transfer platform....
-
§ 38.23(b)(2)(ii) Exception
Where the lift is designed to deploy with its long dimension parallel to the vehicle axis and which pivots into or out of the vehicle while occupied (i.e., “rotary lift”), the requirements...
-
11B-1008.3.1.3 Transfer space
The 48 inch (1219 mm) long minimum dimension of the transfer space shall be centered on and parallel to the 24 inch (610 mm) long minimum side of the transfer platform....
-
Fur out the wall
The centerline of the water closet shall be 16 inches (405 mm) minimum to 18 inches (455 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (430...
-
Height: ADA Standard Section 1008.3.2.2
Each transfer step shall be 8 inches (205 mm) high maximum....
-
Vertical: ADA Standard Section 303.2
Section 303.2 covers the current ADA Standards for vertical changes in level.
-
Rise: ADA Standard Section 405.6
Section 405.6 covers the current ADA Standards for the rise requirements of ramps.
-
11B-405.6 Rise
The rise for any ramp run shall be 30 inches (762 mm) maximum....
-
11B-1008.3.2.2 Height
Each transfer step shall be 8 inches (203 mm) high maximum....
-
11B-406.5.7 Cross slope
The cross slope of curb ramps and blended transitions shall be 1:48 maximum....
-
11B-405.6 Rise
The rise for any ramp run shall be 30 inches (762 mm) maximum....
-
11B-1008.3.2.2 Height
Each transfer step shall be 8 inches (203 mm) high maximum....
-
11B-406.5.7 Cross slope
The cross slope of curb ramps and blended transitions shall be 1:48 maximum....