The clearance between the platform sill and the edge of any runway landing shall be 1¼ inch (32 mm) maximum....
Search Results "Maximum Dimension"
Commonly Searched Documents
-
11B-410.4 Platform to runway clearance
-
Platform to Hoistway Clearance: ADA Standard Section 407.4.3
Section 407.4.3 covers the current ADA Standards for the required clearance between the elevator car platform and the hoistway landing.
-
11B-407.4.3 Platform to hoistway clearance
The clearance between the car platform sill and the edge of any hoistway landing shall be 1¼ inch (32 mm) maximum....
-
11B-809.9.5 Lower shelving
Lower shelving and/or drawer space shall be provided at a height of 48 inches (1219 mm) maximum above the finish floor....
-
11B-809.8.2 Door opening force
The opening force for primary entry exterior doors and secondary exterior doors shall be 8.5 pounds (38 N) maximum....
-
E101.4 Units of Measurement (Section-by-Section Analysis)
This proposed section is new to the 508 Standards and would clarify dimensions stated in the text of the proposed rule....
-
4.13.6 Maneuvering Clearances at Doors
EXCEPTION: Entry doors to acute care hospital bedrooms for in-patients shall be exempted from the requirement for space at the latch side of the door (see dimension “x” in Fig. 25) if the...
-
4.1.6(4)(c)
(ii) Where existing shaft or structural elements prohibit strict compliance with 4.10.9, then the minimum floor area dimensions may be reduced by the minimum amount necessary, but in no...
-
8. Boarding Separately From Wheelchair
(Note, however, that under § 37.165(b), entities are required to accommodate device/user loads and dimensions that exceed the former “common wheelchair” standard, as long as the vehicle...
-
11B-608.2.3 Alternate roll-in type shower compartments
Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
8. Boarding Separately From Wheelchair
(Note, however, that under §37.165(b), entities are required to accommodate device/user loads and dimensions that exceed the former “common wheelchair” standard, as long as the vehicle and...
- Door King Inc. 6050 / 6100 Residential and Commercial Swing Gate Operator
-
11B-1007.2 Accessible routes
Where accessible routes intersect playing surfaces of holes, a 1 inch (25 mm) maximum curb shall be permitted for a width of 32 inches (813 mm) minimum....
-
Gripping Surface: ADA Standard Section 505.6
Section 505.6 covers the current ADA Standards for the handrail gripping surface.
-
11B-505.6 Gripping surface
distance between horizontal projections and the bottom of the gripping surface shall be permitted to be reduced by 1/8 inch (3.2 mm) for each ½ inch (12.7 mm) of additional handrail perimeter dimension...
-
Back Support: ADA Standard Section 903.4
Back support shall be 42 inches (1065 mm) long minimum and shall extend from a point 2 inches (51 mm) maximum above the seat surface to a point 18 inches (455 mm) minimum above the seat...
-
Seats: ADA Standard Section 604.4
Section 604.4 covers the current ADA Standards for the water closet seats.
-
Height: ADA Standard Section 606.3
Section 606.3 covers the current ADA Standards for the height of lavatories and sinks.
-
11B-604.5.1 Side wall
The side wall grab bar shall be 42 inches (1067 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1372 mm) minimum from the rear wall with...
-
11B-407.2.2.3 Audible signals
Audible signals shall have a frequency of 1500 Hz maximum. Verbal annunciators shall have a frequency of 300 Hz minimum and 3000 Hz maximum....
-
11B-608.2.1 Transfer type shower compartments
Transfer type shower compartments shall be 36 inches (914 mm) by 36 inches (914 mm) clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch (914...
-
11B-608.2.3 Alternate roll-in type shower compartments
Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
T505.3 Location of Operable Parts
Operable parts shall be located adjacent to the toe end of the clear space or shall be located no more than 10 inches (255 mm) measured from the centerline of the long dimension of the clear...
-
104.2 Calculation of Percentages
Where the determination of the required size or dimension of an element or facility involves ratios or percentages, rounding down for values less than one half shall be permitted....