branch circuits of 30 amperes or less, communication system receptacles, controls and switches shall be located as follows: Where there is no obstruction, 48 inches (1219 mm) maximum...
Search Results "Maximum Dimension"
-
11B-809.12 Electrical receptacles, controls and switches
-
11B-809.12 Electrical receptacles, controls and switches
branch circuits of 30 amperes or less, communication system receptacles, controls and switches shall be located as follows: Where there is no obstruction, 48 inches (1219 mm) maximum...
-
surface mounted toilet paper dispensers
I feel this should be a future code modification to require at least semi-recessed styles with the maximum allowable projection limited to approximately the grab bar projection limits....
- Door King Inc. 6050 / 6100 Residential and Commercial Swing Gate Operator
-
2. Analysis of footrest clearance height and depth
The range and median values measured on the right-side for these three dimensions are presented in table 2. Critical values are highlighted in yellow....
-
11B-1008.3.2.2 Height
Each transfer step shall be 8 inches (203 mm) high maximum....
-
Height: ADA Standard Section 1008.3.2.2
Each transfer step shall be 8 inches (205 mm) high maximum....
-
Vertical: ADA Standard Section 303.2
Section 303.2 covers the current ADA Standards for vertical changes in level.
-
11B-1008.3.2.2 Height
Each transfer step shall be 8 inches (203 mm) high maximum....
-
11B-405.6 Rise
The rise for any ramp run shall be 30 inches (762 mm) maximum....
-
Rise: ADA Standard Section 405.6
Section 405.6 covers the current ADA Standards for the rise requirements of ramps.
-
11B-405.6 Rise
The rise for any ramp run shall be 30 inches (762 mm) maximum....
-
11B-406.5.7 Cross slope
The cross slope of curb ramps and blended transitions shall be 1:48 maximum....
-
11B-406.5.7 Cross slope
The cross slope of curb ramps and blended transitions shall be 1:48 maximum....
-
1011.2.4 Openings
Elongated openings should be placed so that the long dimension is perpendicular, or as close to perpendicular as possible, to the dominant direction of travel....
-
5.8.2 Knee and Toe Clearance Under Breast Platform
The overall knee and toe space should be increased to a minimum of 28 inches deep, from the initially proposed 25 inch absolute dimension; increasing the knee clearance directly underneath...
-
4.4.2 Head Room
If vertical clearance of an area adjoining an accessible route is reduced to less than 80 in (nominal dimension), a barrier to warn blind or visually-impaired persons shall be provided (...
-
4.4.2 HEAD ROOM
If vertical clearance of an area adjoining an accessible route is reduced to less than 80 in (nominal dimension), a barrier to warn blind or visually-impaired persons shall be provided (...
-
4.10.9 Floor Plan of Elevator Cars
Acceptable door opening and inside dimensions shall be as shown in Fig. 22....
-
4.10.9 FLOOR PLAN OF ELEVATOR CARS
Acceptable door opening and inside dimensions shall be as shown in Fig. 22....
-
1011.2.4 Openings
Elongated openings should be placed so that the long dimension is perpendicular, or as close to perpendicular as possible, to the dominant direction of travel....
-
§ 38.159(b)(2)(ii) Exception
Where the lift is designed to deploy with its long dimension parallel to the vehicle axis and which pivots into or out of the vehicle while occupied (i.e., “rotary lift”), the requirements...
-
608.2.2 Standard Roll-In Type Shower Compartments
Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides...