Terry, You should identify the minimum dimensions of the clear floor space at the Lav....
Search Results "Maximum Dimension"
-
Clear floor space at Lav
-
Line Spacing: ADA Standard Section 703.5.9
Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height....
-
Height: ADA Standard Section 1009.4.2
The height of the transfer wall shall be 16 inches (405 mm) minimum and 19 inches (485 mm) maximum measured from the deck....
-
11B-703.5.9 Line spacing
Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height....
-
11B-1009.4.2 Height
The height of the transfer wall shall be 16 inches (406 mm) minimum and 19 inches (483 mm) maximum measured from the deck....
-
11B-1009.4.2 Height
The height of the transfer wall shall be 16 inches (406 mm) minimum and 19 inches (483 mm) maximum measured from the deck....
-
11B-703.5.9 Line spacing
Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height....
-
M302.2.3 Size (Section-by-Section Analysis)
increased to 17 inches, a disability advocate recommended increasing the width to 23 inches, two of the commenters, accessibility consultant and disability advocate, stated that the proposed dimensions...
-
5.8.2.5 Toe Height Recommendation
A toe space dimension usually defines a static unobstructed space. However, in the case of mammography, as the breast platform moves up and down, the toe space changes....
-
Parallel Approach: ADA Standard Section 704.2.1.1
Where a parallel approach is provided, the distance from the edge of the telephone enclosure to the face of the telephone unit shall be 10 inches (255 mm) maximum....
-
Handrail Height: ADA Standard Section 1008.2.5.3.2
The top of handrail gripping surfaces shall be 20 inches (510 mm) minimum and 28 inches (710 mm) maximum above the ramp surface....
-
Height: ADA Standard Section 902.4.2
The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (760 mm) maximum above the finish floor or ground....
-
Tray Slides: ADA Standard Section 904.5.2
The tops of tray slides shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the finish floor or ground....
-
Incidental Spaces: ADA Standard Section 206.7.3
Section 206.7.3 covers scoping requirements in the most current ADA Standards for accessible routes to incidental spaces.
-
11B-902.4.2 Height
The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (762 mm) maximum above the finish floor or ground....
-
11B-1008.2.5.3.2 Handrail height
The top of handrail gripping surfaces shall be 20 inches (508 mm) minimum and 28 inches (711 mm) maximum above the ramp surface....
-
11B-704.2.1.1 Parallel approach
Where a parallel approach is provided, the distance from the edge of the telephone enclosure to the face of the telephone unit shall be 10 inches (254 mm) maximum....
-
11B-602.8 Depth
Wall- and post-mounted cantilevered drinking fountains shall be 18 inches (457 mm) minimum and 19 inches (483 mm) maximum in depth....
-
11B-705.1.2.6 Reflecting pools
When detectable warnings are provided at reflecting pools, it shall be 24 inches (610 mm) minimum and 36 inches (914 mm) maximum in width....
-
11B-206.7.3 Incidental spaces
Platform lifts shall be permitted to provide an accessible route to incidental spaces which are not public use spaces and which are occupied by five persons maximum....
-
11B-904.5.2 Tray slides
The tops of tray slides shall be 28 inches (711 mm) minimum and 34 inches (864 mm) maximum above the finish floor or ground....
-
11B-904.5.2 Tray slides
The tops of tray slides shall be 28 inches (711 mm) minimum and 34 inches (864 mm) maximum above the finish floor or ground....
-
11B-1008.2.5.3.2 Handrail height
The top of handrail gripping surfaces shall be 20 inches (508 mm) minimum and 28 inches (711 mm) maximum above the ramp surface....
-
11B-902.4.2 Height
The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (762 mm) maximum above the finish floor or ground....