Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (432 mm) minimum under the element. Exceptions: 1. ...
Search Results "Sign Clear Floor Space"
-
11B-306.2.3 Minimum required depth
-
11B-306.2.3 Minimum required depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (432 mm) minimum under the element....
-
Trailhead Signs
Locate trailhead information signs centered at the back of a 30- by 48-inch (760- by 1,220-millimeter) -minimum clear floor or ground space....
-
3) Where the standard says "Changes in level are not permitted", but no advisory follows the standard
3) Where the standard says "Changes in level are not permitted", but no advisory follows the standard, such as 404.2.4.4 floor or ground surfaces at doors: Although the Advisory at 304.2...
-
4.5.2.1 Forward Approach
The clear floor or ground space for a forward approach shall be 36 inches (915 mm) by 48 inches (1220 mm)....
-
4.5.2.2 Side Approach
The clear floor or ground space for a side approach shall be 30 inches (760 mm) by 60 inches (1525 mm)....
-
803.3 Door Swing
Doors shall not swing into the room unless a clear floor or ground space complying with 305.3 is provided beyond the arc of the door swing....
-
803.3 Door Swing
Doors shall not swing into the room unless a clear floor or ground space complying with 305.3 is provided beyond the arc of the door swing....
-
Approach and Maneuvering Clearance [§305.6 and §305.7]
Approach and Maneuvering Clearance [§305.6 and §305.7] Where the space is obstructed on both sides for more than half the depth, additional clearance is required for maneuvering....
-
I1a
For a side approach (clear floor space at least 30 inches long x 48 inches wide), is the coin slot no higher than 54 inches above the floor?...
-
I1b
For a front approach (where clear floor space at least 30 inches wide x 48 inches long), is the coin slot no higher than 48 inches above the floor?...
-
4.22.2 Doors
Doors shall not swing into the clear floor space required for any fixture....
-
4.22.2 DOORS
Doors shall not swing into the clear floor space required for any fixture....
- Pilot Rock CN-R/R Round Receptacle Perforated Steel
- Pilot Rock CN-S7101A Kolorcans Round Trash Receptacle With Dome Lid
- Pilot Rock BPR1 Bear Resistant Trash Receptacle
- Landscape Forms Inc. MutipliCITY Trash Receptacle
- Landscape Forms Inc. Central Park Conservancy Recycling System
- Magnuson Group MECORA Outdoor Waste Receptacle
- Landscape Forms Inc. Austin Trash Receptacle
- Magnuson Group RETTO Outdoor Waste Receptacle
- Landscape Forms Inc. 35 Pitch Trash Receptacle
- Pilot Rock CN-R/D Trash Receptacle
- Pilot Rock CN-S7801A Kolorcans Square Trash Receptacle With Dome Lid