A 36 inch (914 mm) wide minimum by 60 inch (1524 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. [2010 ADA Standards] 608.2.2.1...
Search Results "Sign Clear Floor Space"
-
11B-608.2.2.1 Clearance
-
4.15.5(1)
(1) Wall- and post-mounted cantilevered units shall have a clear knee space between the bottom of the apron and the floor or ground at least 27 in (685 mm) high, 30 in (760 mm) wide, and...
-
4.15.5(1)
(1) Wall- and post-mounted cantilevered units shall have a clear knee space between the bottom of the apron and the floor or ground at least 27 in (685 mm) high, 30 in (760 mm) wide, and...
- Figure 1009.4.1 Clear Deck Space at Transfer Walls – Drawing from the U.S. Access Board
-
606.2 Clear Floor Space (Exception 3)
606.2 Clear Floor Space (Exception 3) This section requires clear floor space positioned for a forward approach and knee and toe clearance to be provided at lavatories and sinks....
-
902.4.1 Clear Floor or Ground Space
A clear floor space complying with 305 positioned for forward approach shall be provided....
-
902.4.1 Clear Floor or Ground Space
A clear floor space complying with 305 positioned for forward approach shall be provided....
-
11B-703.8.9 Height above floor
Low resolution VMS characters shall be 40 inches (1016 mm) minimum above the floor of the viewing position, measured to the baseline of the character....
-
11B-703.8.9 Height above floor
Low resolution VMS characters shall be 40 inches (1016 mm) minimum above the floor of the viewing position, measured to the baseline of the character....
-
1015.2 Clear Ground Space
This section requires a clear ground space 36 inches minimum by 48 inches minimum positioned for either a forward or parallel approach to be provided at each distinct viewing location, and...
-
4.2.8 Slope
The slope of the clear floor or ground space required by section 4.2.6 shall not exceed 1:48 (2 percent) in any direction. Exception....
-
4.5.3 Slope
The slope of the clear floor or ground space for trash, recycling, and other essential containers shall not exceed 1:48 (2 percent) in any direction. Exception....
-
11B-407.2.3.1 Floor designation
Floor designations complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of elevator hoistway entrances....
-
11B-407.2.3.1 Floor designation
Floor designations complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of elevator hoistway entrances....
-
Side Approach
Side Approach Clear space for a side approach is specified for units that are free-standing or built-in....
- Figure 604.3.2 (Exception) Overlap of Water Closet Clearance in Residential Dwelling Units – Drawing from the U.S. Access Board
- Figure 810.3 Bus Shelters – Drawing from the U.S. Access Board
-
11B-904.4.1 Parallel approach
A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum above the finish floor shall be provided....
-
11B-904.4.1 Parallel approach
A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum above the finish floor shall be provided....
-
11B-904.4.1 Parallel approach
A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum above the finish floor shall be provided....
-
10.3.1(17)
EXCEPTION: Elevator cars with a clear floor area in which a 60 inch diameter circle can be inscribed may be substituted for the minimum car dimensions of 4.10, Fig. 22....
-
11B-304.2 Floor or ground surfaces
Floor or ground surfaces of a turning space shall comply with Section 11B-302. Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted....