Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear...
Search Results "Sign Clear Floor Space"
-
604.3.1 Size
-
11B-604.3 Clearance
11B-604.3 Clearance. Clearances around water closets and in toilet compartments shall comply with Section 11B-604.3.
-
11B-604.3 Clearance
Clearances around water closets and in toilet compartments shall comply with Section 11B-604.3.
-
604.3 Clearance
604.3 Clearance. Clearances around water closets and in toilet compartments shall comply with 604.3.
-
604.3 Clearance
Clearances around water closets and in toilet compartments shall comply with 604.3.
-
604.3.1 Size
Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear...
-
604.3.1 Size
604.3.1 Size. Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular...
- Figure 1009.2.3 Clear Deck Space at Pool Lifts – Drawing from the U.S. Access Board
-
R304.5.5 Clear Space
R304.5.5 Clear Space....
-
4.5.6 Openings
Openings in the clear floor or ground space surface shall not allow passage of a sphere more than 1/2 inch (13 mm) diameter....
-
Floor or Ground Surface: ADA Standard Section 403.2
Section 403.2 covers the current ADA Standards for floor or ground surfaces that are part of an accessible route.
-
11B-1008.2.6 Ground surfaces
Ground surfaces on accessible routes, clear floor or ground spaces, and turning spaces shall comply with Section 11B-1008.2.6. [2010 ADAS] Advisory 1008.2.6 Ground Surfaces. ...
-
11B-1008.2.6 Ground surfaces
Ground surfaces on accessible routes, clear floor or ground spaces, and turning spaces shall comply with Section 11B-1008.2.6. [2010 ADAS] Advisory 1008.2.6 Ground Surfaces....
-
11B-1008.2.6 Ground surfaces
Ground surfaces on accessible routes, clear floor or ground spaces, and turning spaces shall comply with Section 11B-1008.2.6. Advisory 11B-1008.2.6 Ground surfaces....
-
H13
Is the operating control (switch, lever, button, or pull) of at least one of each type of dispenser or built-in equipment no higher than 54 inches above the floor (if there is clear floor...
-
11B-604 Water closets and toilet compartments
clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear...
-
Size and Clearances [4.21.2]
Size and Clearances [4.21.2] Lavatories can be located within the clear floor space (as shown in ADAAG Figure 35)....
-
11B-809.10.6.3 Floor space
A clear maneuvering space 30 inches (762 mm) wide minimum by 48 inches (1219 mm) minimum in length shall be located outside the shower, with the width flush with the control wall and the...
-
Exercise Machines and Equipment
Section 236 of the 2010 Standards requires at least one of each type of exercise machine to meet clear floor space requirements of section 1004.1....
-
1134A.6, Item 3
Floor space. ...
-
1134A.6, Item 3
Floor space....
-
Floor or Ground Surface: ADA Standard Section 1002.4.1
The floor or ground surface of wheelchair spaces shall be stable and firm....
-
11B-306.2.3 Minimum required depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (432 mm) minimum under the element....
-
Size and Clearances [4.21.2]