measures 30" W x 16" D with back measurements of 16"W x 7" H W x 7" H. Weighs 24lbs. for easy transport. Custom sizes available. 5 year warranty....
Search Results "Tape Measure"
- Acess-Able Designs Portable Tub/Shower Transfer Bench SH-425
-
1 [§ 4.7.3]
1 [§ 4.7.3] Only measure the width of the ramp section of the curb ramp (labeled “ramp” to the right [below]). The ramp section of a curb ramp is also known as the “ramp run.”...
-
11B-407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in Section 11B-308, measured to the centerline of the highest operable part. Exception: Reserved....
-
Door Pressure Gauge
Door Pressure Gauge This Door Pressure Gauge, available from Evan Terry Associates, measures forces from 0-35 pounds on one side and 0-16 kilograms on the other....
-
Digital inclinometers (SmartTool®)
Digital inclinometers (SmartTool®), while slightly more expensive than standard levels, are easy to calibrate and use and can measure slopes in degrees, percent, and fractions per foot....
-
11B-407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in Section 11B-308, measured to the centerline of the highest operable part. Exception: Reserved....
-
11B-407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in Section 11B-308, measured to the centerline of the highest operable part. Exception: Reserved....
-
TEST NO. 1 – INDIVIDUAL BUILDING TEST
The slopes of the undisturbed site measured between the planned entrance and all vehicular or pedestrian arrival points within 50 feet (15 240 mm) of the planned entrance exceed 15 percent...
-
D. Election Day Compliance Review
In the materials provided to each in-precinct Election Coordinator, the Board will include a checklist of the temporary measures to be implemented during the voting period at each...
-
TEST NO. 1 – INDIVIDUAL BUILDING TEST
The slopes of the undisturbed site measured between the planned entrance and all vehicular or pedestrian arrival points within 50 feet (15 240 mm) of the planned entrance exceed 15 percent...
-
11B-233.3.1.2.6.2 Test number one, individual building test
The slopes of the undisturbed site measured in a straight line between the planned entrance and all vehicular or pedestrian arrival points within 50 feet (15,240 mm) of the planned entrance...
-
TEST NO. 1 – INDIVIDUAL BUILDING TEST
It is not required by this code to provide an accessible route when the terrain of the site is such that both of the following apply: The slopes of the undisturbed site measured between...
- Better Living AVIVA Soap Dispenser 1
-
Purpose of the project
Purpose of the project Accessibility standards reference industry guidance in the measure of field and construction tolerances....
- Redi Free® with Redi Base® Shower Pans
- Redi Free® with Redi Trench® Shower Pans
- Stabila, Inc. Tech Digital Electronic Level Type 196-2
- Nova Health Products LiteRamp 6' Wheelchair and Scooter Ramp (LR6)
-
M303.2.4.2.2 Height
Wheelchair spaces shall include toe clearance 9 inches (230 mm) high minimum above the floor measured to a depth of 6 inches (150 mm) maximum measured from the toe end of the wheelchair...
-
Identification: ADA Standard Section 502.6
Section 502.6 covers the current ADA Standards for parking space identification signs.
-
11B-604.9.6 Dispensers
Toilet paper dispensers shall comply with Section 11B-309.4 and shall be 7 inches (178 mm) minimum and 9 inches (229 mm) maximum in front of the water closet measured to the centerline of...
-
General: ADA Standard Section 306.1
Section 306.1 of the ADA Standards covers information in the current ADA Standards for knee and toe clearance.
-
Visible Signals: ADA Standard Section 407.2.2.2