., concrete, brick, flagstone) may have a maximum change in height from the interior landing of 4 inches (101.6 mm)....
Search Results "Feasibility (Technical, Infeasible, Structural, Maximum Extent)"
-
1132A.4, Item 3
-
1607A.8.2 Grab bars, shower seats and dressing room bench seats
room bench seat systems shall be designed to resist a single concentrated load of 250 pounds (1.11 kN) applied in any direction at any point on the grab bar or seat so as to produce the maximum...
-
1134A.6, Item 1.2
A water closet may project a maximum of 12 inches (305 mm) into the opening provided that a minimum of 36 inches (914 mm) clear space is maintained between the water closet and the shower...
-
4.28.3(7)
large rooms and spaces exceeding 100 ft (30 m) across, without obstructions 6 ft (2 m) above the finish floor, such as auditoriums, devices may be placed around the perimeter, spaced a maximum...
-
Controls
Controls Push buttons or plates and switches are subject to relevant requirements for controls and operating mechanisms, including the maximum 5 Ib operating force....
-
4.13.11* DOOR OPENING FORCE
The maximum force for pushing or pulling open a door shall be as follows: (1) Fire doors shall have the minimum opening force allowable by the appropriate administrative authority....
-
1011.7 Outdoor Rinsing Showers
The hand-held shower spray unit is required to have at least one fixed position located 15 inches minimum and 48 inches maximum above the ground....
-
3.4.3 Unrestricted Viewing Opportunities
required to be accessible by section 3.4.1 shall provide at least one unrestricted viewing opportunity that accommodates eye levels between 32 inches (815 mm) minimum and 51 inches (1295 mm) maximum...
-
2.4.1 Running Slope (Grade)
Running Slope (Grade) and Resting Intervals Running Slope (Grade) of Segment of Outdoor Recreation Access Route Maximum Length of Segment Between Resting Intervals ...
-
4.34.6.10* KITCHEN STORAGE
Cabinets, drawers, and shelf areas shall comply with 4.25 and shall have the following features: (1) Maximum height shall be 48 in (1220 mm) for at least one shelf of all cabinets and...
-
2.3.1
For example, specifications may include limits on the number of local variations (dips and humps) on an accessible ramp to a maximum of 10 percent slope for no more than 20 percent of the...
-
11B-502.6.4.1
The centerline of the International Symbol of Accessibility shall be a maximum of 6 inches (152 mm) from the centerline of the parking space, its sides parallel to the length of the parking...
-
11B-407.2.1.4 Location
Responding cars are programmed for maximum efficiency by reducing the number of stops any passenger experiences....
-
1607A.8.2 Grab bars, shower seats and dressing room bench seats
room bench seat systems shall be designed to resist a single concentrated load of 250 pounds (1.11 kN) applied in any direction at any point on the grab bar or seat so as to produce the maximum...
-
11B-809.10.7.2 Location
The centerline of the water closet shall be 17 inches (432 mm) minimum to 18 inches (457 mm) maximum from a wall or partition that is 54 inches (1372 mm) minimum in length....
-
Toilet Paper Dispensers
The provisions for toilet paper dispensers at section 604.7 of the 2010 Standards require the dispenser to be located seven inches minimum and nine inches maximum in front of the water closet...
-
11B-703.3.1 Dimensions and capitalization
TABLE 11B-703.3.1 BRAILLE DIMENSIONS MEASUREMENT RANGE MINIMUM IN INCHES MAXIMUM IN INCHES Dot base diameter...
-
Features of Accessible Parking Spaces
Access aisle width is at least 60 inches, must be at the same level and the same length as the adjacent parking space(s) it serves, maximum slope in all directions is 1:48, and access aisle...
-
11B-703.3.1 Dimensions and capitalization
TABLE 11B-703.3.1 BRAILLE DIMENSIONS MEASUREMENT RANGE MINIMUM IN INCHES MAXIMUM IN INCHES Dot base diameter 0.059 (1.5 mm) to 0.063 (1.6 mm)...
-
11B-703.3.1 Dimensions and capitalization
TABLE 11B-703.3.1 BRAILLE DIMENSIONS MEASUREMENT RANGE MINIMUM IN INCHES MAXIMUM IN INCHES Dot base diameter...
-
2.2.3 Functional Reach
Use of the electromechanical probe required manually digitizing the 3-D location of the maximum reach point after the cylinder was positioned (Figure 2‒3)....
-
Accessibility - Flatness and Lippage
Mortar setting beds for concrete pavers and paving slabs Joint width between paving units with chamfers (See Figure I) Maximum 3/8 in. (10 rom) - The surface of the mortared joint...
-
Hologic, Inc.
As a result of these technical and clinical use constraints, the minimum possible table height in the table shown in Figure 1 is 37 inches....
-
Section 36.207 Places of Public Accommodation Located in Private Residences (Section-By-Section Analysis and Response to Comments)
Paragraph (b) was added in response to comments that sought clarification on the extent of coverage of the private residence used as the place of public accommodation....