Unless otherwise specified, clear floor or ground space shall be positioned for either forward or parallel approach to an element....
Search Results "Water Closet Clear Floor Space"
-
305.5 Position
-
305.3 Size
The clear floor or ground space shall be 30 inches (760 mm) minimum by 48 inches (1220 mm) minimum....
-
305.3 Size
The clear floor or ground space shall be 30 inches (760 mm) minimum by 48 inches (1220 mm) minimum....
-
305.3 Size
The clear floor or ground space shall be 30 inches (760 mm) minimum by 48 inches (1220 mm) minimum....
-
11B-305.3 Size
The clear floor or ground space shall be 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum....
-
11B-305.3 Size
The clear floor or ground space shall be 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum....
-
Clear Floor Space [4.25.2] and Height [4.25.3]
Clear Floor Space [4.25.2] and Height [4.25.3] Clear floor space for either a forward or side approach is allowed....
-
11B-602.2 Clear floor space
Units shall have a clear floor or ground space complying with Section 11B-305 positioned for a forward approach and centered on the unit....
-
11B-602.2 Clear floor space
Units shall have a clear floor or ground space complying with Section 11B-305 positioned for a forward approach and centered on the unit....
-
3.3.4 Clear Floor Length
3.3.4 Clear Floor Length The mean value of clear floor length for our study (1250 mm or 49 in.) is above the clear floor length provided in the U.S. standards (1220 mm or 48 in.)....
- Bobrick Accessibility Video -- Design for Turning Radiuses
-
11B-804.3.1 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for a forward approach shall be provided....
-
11B-804.3.1 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for a forward approach shall be provided....
-
11B-804.3.1 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for a forward approach shall be provided....
-
Clear Floor Space: Minimum Clear Floor Space Required - Manual, Power & Scooter
Clear floor area dimensions are used for determining the size of spaces designated for wheeled mobility users (such as on buses, in movie theaters, sports stadiums)....
-
1002.6.1 Clear Floor or Ground Space
1002.6.1 Clear Floor or Ground Space. A clear floor or ground space complying with 305 shall be provided in the load and unload area adjacent to the transfer device....
- Delta Toilet Installation Video
-
11B-608.2.2.1 Clearance
A 36 inch (914 mm) wide minimum by 60 inch (1524 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. [2010 ADA Standards] 608.2.2.1...
-
11B-608.2.2.1 Clearance
A 36 inch (914 mm) wide minimum by 60 inch (1524 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. [2010 ADA Standards] 608.2.2.1...
-
11B-604.9.1 Location
The water closet shall be located with a wall or partition to the rear and to one side....
-
11B-604.9.1 Location
The water closet shall be located with a wall or partition to the rear and to one side....
-
5.1.6 Clear Floor or Ground Space
A clear floor or ground space at least 36 inches (915 mm) by 48 inches (1220 mm) shall be provided parallel to the entrance to the camp shelter....
-
306.1 General
Where space beneath an element is included as part of clear floor or ground space or turning space, the space shall comply with 306....
-
306.1 General
Where space beneath an element is included as part of clear floor or ground space or turning space, the space shall comply with 306....