At water hydrants, a minimum of 72 by 48 inches of clear ground space must be provided with the long side of the space adjoining or overlapping an ORAR or trail as applicable, or another...
Search Results "Water Closet Clear Floor Space"
Commonly Searched Documents
-
Water Hydrants and Water Spouts [1011.2, 1011.3, and 1011.6]
-
Bathroom Accommodating Reduced Ambulatory Mobility
Ceiling lift between the bathtub and toilet (this is actually fun to use) – reinforcement less than $50 Chromatherapy bathtub for relaxation FSC certified maple floor...
-
306.2.3 Minimum Required Depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element....
-
306.2.3 Minimum Required Depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element....
-
306.2.3 Minimum Required Depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element....
- Everclean Toilets by American Standard
-
Zurn Model Z5560 Commercial EcoVantage ADA Height Elongated Toilet: Pressure-Assist Replacement Tank Kit Video
Requires the Registered User plan or above. Login!
-
5.3.2.1 Size
The clear floor or ground space shall be 60 inches (1525 mm) wide minimum measured parallel with the back of the pit toilet, and 56 inches (1420 mm) deep minimum measured parallel to the...
-
11B-809.10.7.2 Location
Water closets shall be located within bathrooms in a manner that permits a grab bar to be installed on at least one side of the fixture....
-
1134A.8, Item 2
Floor space. A clear maneuvering space at least 30 inches by 48 inches (762 mm by 1219 mm) shall be provided at lavatories and shall be centered on the lavatory....
-
1134A.8, Item 2
Floor space. A clear maneuvering space at least 30 inches by 48 inches (762 mm by 1219 mm) shall be provided at lavatories and shall be centered on the lavatory....
-
4.2.4.1 Size and Approach
The minimum clear floor or ground space required to accommodate a single, stationary wheelchair and occupant is 30 in by 48 in (760 mm by 1220 mm) (see Fig. 4(a))....
-
Accessible Miniature Golf Course Holes
Sections 239.2 and 1007.3 of the 2010 Standards require at least fifty percent (50%) of golf holes on miniature golf courses to be accessible, including providing a clear floor or ground...
- Willoughby Industries ASETWS-1490-FM-HC Ligature-Resistant Floor Mounted Siphon Jet Water Closet
-
305.5 Position
Unless otherwise specified, clear floor or ground space shall be positioned for either forward or parallel approach to an element....
-
11B-305.5 Position
Unless otherwise specified, clear floor or ground space shall be positioned for either forward or parallel approach to an element....
-
Space Needs
Percentage of subjects who were able to transfer within each clear floor space dimension for Protocol A transfer TO and FROM the platform at their maximum height (Max) and minimum height...
-
305.5 Position
Unless otherwise specified, clear floor or ground space shall be positioned for either forward or parallel approach to an element. ...
-
11B-305.2 Floor or ground surfaces
Floor or ground surfaces of a clear floor or ground space shall comply with Section 11B-302....
-
11B-606.2 Clear floor space
A clear floor space complying with Section 11B-305, positioned for a forward approach, and knee and toe clearance complying with Section 11B-306 shall be provided. Exceptions: 1....
-
4.13.5 CLEAR WIDTH
Doorways shall have a minimum clear opening of 32 in (815 mm) with the door open 90 degrees, measured between the face of the door and the stop (see Fig. 24(a), (b), (c), and (d))....
- Willoughby Industries ASETW1490FM Ligature-Resistant Floor Mounted Blowout Series Water Closet
-
11B-306.3.3 Minimum required depth
Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (279 mm) deep minimum at 9 inches (229 mm) above the finish floor...
-
11B-306.3.3 Minimum required depth
Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (279 mm) deep minimum at 9 inches (229 mm) above the finish floor...