A clear ground space shall be provided at the entrance to the camp shelter....
Search Results "Water Closet Clear Floor Space"
-
1014.2.1.1 Clear Ground Space
-
604 Water Closets and Toilet Compartments
(This section is to be used for toilet buildings with multiple risers provided at recreation sites with a FS Recreation Site Development Scale of 3 or higher, and for the Exception...
-
604.3.1 Size
Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear wall....
-
ATM Clear Floor or Ground Space
Sections 707.2 and 707.3 address clear floor or ground space requirements and operable parts, respectively. These provisions include exceptions for drive-up only ATMs....
-
1015.2 Clear Ground Space
This section requires a clear ground space 36 inches minimum by 48 inches minimum positioned for either a forward or parallel approach to be provided at each distinct viewing location, and...
-
§ 38.107(a)(1)
(1) The minimum clear floor area shall be 35 inches by 60 inches....
-
11B-809.10.8.2 Floor space
A floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be provided centered on the lavatory....
-
1011.2 Clear Ground Space
A clear ground space complying with 1011.2 shall be provided at outdoor constructed features. EXCEPTIONS: 1. ...
-
11B-809.10.7.3 Reinforcement for grab bars
Where water closets are placed adjacent to a side wall, reinforcement shall be installed on both sides or one side and the back....
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide...
-
Turning Space: ADA Standard Section 803.2
Turning space complying with 304 shall be provided within the room....
-
11B-304.2 Floor or ground surfaces
Floor or ground surfaces of a turning space shall comply with Section 11B-302. Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted....
-
1009.4.1 Clear Deck Space
1009.4.1 Clear Deck Space....
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide...
-
1009.4.1 Clear Deck Space
A clear deck space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
R404 Clear Spaces (Section-by-Section Analysis)
R404 Clear Spaces (Section-by-Section Analysis) Clear spaces are required at operable parts (see R403.2), including accessible pedestrian signals and pedestrian pushbuttons (see R209)...
-
11B-305.6 Approach
One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space....
-
11B-305.6 Approach
One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space....
-
11B-304.2 Floor or ground surfaces
Floor or ground surfaces of a turning space shall comply with Section 11B-302. Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted....
-
11B-604 WATER CLOSETS AND TOILET COMPARTMENTS
-
1008.2.3 Water Play Components
1008.2.3 Water Play Components. Accessible routes serving water play components shall be permitted to use the exceptions in 1008.2.3. EXCEPTIONS: 1....
-
11B-809.10.7.3 Reinforcement for grab bars
Where water closets are placed adjacent to a side wall, reinforcement shall be installed on both sides or one side and the back....
-
1008.2.3 Water Play Components
Where the surface of the accessible route, clear floor or ground spaces, or turning spaces serving water play components is submerged, compliance with 302, 403.3, 405.2, 405.3, and 1008.2.6...
-
11B-604.9.2 Clearance
Clearance around a water closet shall comply with Section 11B-604.3....