A portion of the counter surface that is 36 inches (915 mm) long minimum and 36 inches (915 mm) high maximum above the finish floor shall be provided....
Search Results "Water Closet Clear Floor Space"
Commonly Searched Documents
-
Parallel Approach: ADA Standard Section 904.4.1
-
Is clear floor space required to be centered on elements?
The standards require the clear floor space to be centered on wheelchair accessible drinking fountains (forward approach), kitchen work surfaces, (forward approach), and washers and dryers...
-
4.3.2 Clear Floor or Ground Space
Tent pads and tent platforms shall have clear floor or ground space surrounding the tent that is at least 48 inches (1220 mm) wide. This space shall not overlap the ORAR. Exception....
- Willoughby Industries ETW-1490-FM-HC Floor Mounted Blowout Series Water Closet
-
§27.71(k)(2) Clear floor or ground space.
(2) Clear floor or ground space. A clear floor or ground space complying with section 305 of the U.S....
-
§ 27.71(k)(2) Clear floor or ground space
(2) Clear floor or ground space. A clear floor or ground space complying with section 305 of the U.S....
-
§ 382.57(c)(2) Clear floor or ground space
(2) Clear floor or ground space. A clear floor or ground space complying with section 305 of the U.S....
-
4.24.5 Clear Floor Space
A clear floor space at least 30 in by 48 in (760 mm by 1220 mm) complying with 4.2.4 shall be provided in front of a sink to allow forward approach....
-
4.24.5 CLEAR FLOOR SPACE
A clear floor space at least 30 in by 48 in (760 mm by 1220 mm) complying with 4.2.4 shall be provided in front of a sink to allow forward approach....
-
808.3 Clear Floor Space
808.3 Clear Floor Space. Each jury box and witness stand shall have, within its defined area, clear floor space complying with 305....
-
Bus Shelters: ADA Standard Section 810.3
Bus shelters shall provide a minimum clear floor or ground space complying with 305 entirely within the shelter....
-
11B-810.3 Bus shelters
Bus shelters shall provide a minimum clear floor or ground space complying with Section 11B-305 entirely within the shelter....
- Geberit Monolith Installation
-
Clear Floor Space: Minimum Clear Floor Space Required for Forward and Side Approach - Scooter
This data depicts the amount of clear floor area required by persons using wheeled mobility devices when performing a forward or side reach to a target location (e.g., reaching to a...
-
7.4.11.1 Clear Space
Trailhead signs shall be located centered at the back of a 30- by 48-inch (760- by 1,220-millimeter) minimum clear floor or ground space....
- How to Remove and Install a Toilet from American Standard
-
604 Water Closets and Toilet Compartments
[See subsections ...]
-
604 Water Closets and Toilet Compartments
[See subsections ...]
-
Technical Memorandum TM 2013-19 Private Toilet and Bathing Rooms
Water Closets 604.4, Exception 1: Seats 604.5, Exception 1: Grab Bars. Lavatories and Sinks 606.2, Exception 2: Clear Floor Space 606.3, Exception 1: Height....
-
§ 38.123(a)(1)
(1) The minimum clear floor area shall be 35 inches by 60 inches....
-
11B-1002.6.1 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided in the load and unload area adjacent to the transfer device....
-
11B-1002.6.1 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided in the load and unload area adjacent to the transfer device....
-
11B-1002.6.1 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided in the load and unload area adjacent to the transfer device....
-
Plumbing/Restrooms
PLUMBING/RESTROOMS Turning space within the room 11B-603 Door swing not in clear floor space of any fixture (except...