Desk clear floor space: If provided, desks and writing tables need to have a 30-inch by 48-inch clear floor space that extends 19 inches under the desk and any fixed seat needs to be removable...
Search Results "Water Closet Clear Floor Space"
-
3. Desk clear floor space
-
4.2.4.2 RELATIONSHIP OF MANEUVERING CLEARANCE TO WHEELCHAIR SPACES
One full unobstructed side of the clear floor or ground space for a wheelchair shall adjoin or overlap an accessible route or adjoin another wheelchair clear floor space....
-
1004.1 Clear Floor Space
Clear floor or ground spaces required at exercise machines and equipment shall be permitted to overlap. Advisory 1004.1 Clear Floor Space....
-
1004.1 Clear Floor Space
Clear floor or ground spaces required at exercise machines and equipment shall be permitted to overlap. Advisory 1004.1 Clear Floor Space....
-
11B-1008.2.6 Ground surfaces
Ground surfaces on accessible routes, clear floor or ground spaces, and turning spaces shall comply with Section 11B-1008.2.6. Advisory 11B-1008.2.6 Ground surfaces....
-
11B-1008.2.6 Ground surfaces
Ground surfaces on accessible routes, clear floor or ground spaces, and turning spaces shall comply with Section 11B-1008.2.6. Advisory 11B-1008.2.6 Ground surfaces....
-
611.2 Clear Floor Space
611.2 Clear Floor Space. A clear floor or ground space complying with 305 positioned for parallel approach shall be provided....
-
11B-809.10.6.3 Floor space
A clear maneuvering space 30 inches (762 mm) wide minimum by 48 inches (1219 mm) minimum in length shall be located outside the shower, with the width flush with the control wall and the...
-
4.2.4.2 Relationship of Maneuvering Clearance to Wheelchair Spaces
One full unobstructed side of the clear floor or ground space for a wheelchair shall adjoin or overlap an accessible route or adjoin another wheelchair clear floor space....
-
604.8.1.7 Water closet
604.8.1.7 Water closet. In new construction, the accessible water closet within the wheelchair accessible compartment shall be located in the corner, diagonal to the door....
-
602.2 Clear Floor Space
602.2 Clear Floor Space. Units shall have a clear floor or ground space complying with 305 positioned for a forward approach and centered on the unit....
-
Clear Floor Space [§309.2]
Clear Floor Space [§309.2] Clear floor space for forward approaches must extend up to or, if knee or toe space is provided, below operable parts....
-
4.2.4.3 Surfaces for Wheelchair Spaces
Clear floor or ground spaces for wheelchairs shall comply with 4.5....
-
4.2.4.3 SURFACES FOR WHEELCHAIR SPACES
Clear floor or ground spaces for wheelchairs shall comply with 4.5....
-
611.2 Clear Floor Space
A clear floor or ground space complying with 305 positioned for parallel approach shall be provided. The clear floor or ground space shall be centered on the appliance....
-
611.2 Clear Floor Space
A clear floor or ground space complying with 305 positioned for parallel approach shall be provided. The clear floor or ground space shall be centered on the appliance....
-
11B-306.2.3 Minimum required depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (432 mm) minimum under the element....
-
11B-306.2.3 Minimum required depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (432 mm) minimum under the element....
-
Clear Floor Space
Clear Floor Space The load and unload areas adjacent to transfer devices must have a clear space of 30 by 48 inches minimum....
- Caroma® USA Invisi Series II Walvit Wall Hung Elongated Water Closet
-
Door Swing: ADA Standard Section 803.3
Doors shall not swing into the room unless a clear floor or ground space complying with 305.3 is provided beyond the arc of the door swing....
-
804.3.1 Clear Floor or Ground Space
804.3.1 Clear Floor or Ground Space. A clear floor space complying with 305 positioned for a forward approach shall be provided....
-
Wheelchair Space for Seat Transfer
Commenters indicated that this provision could be misinterpreted as allowing the space to be provided in front of the bench at one end....