Extension shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight. ...
Search Results "End Transfer Surface"
Commonly Searched Documents
-
505.10.3 Bottom Extension at Stairs
-
1132A.4, Item 1
., concrete, brick, flagstone) serving primary entry doors and required exit doors are limited to not more than ½ inch (12.7 mm) of change in height between floor surfaces....
-
11B-505.10.2 Top extension at stairs
Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight. ...
-
11B.707.7.1.3 Horizontally mounted display screen
60 degrees to 90 degrees (horizontal) from vertical, the center line of the display screen and other display devices shall be no more than 34 inches (864 mm) above the floor or ground surface...
-
11B-505.10.2 Top extension at stairs
Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight....
-
11B-404.2.9 Door and gate opening force
and the centerline of the second push plate shall be 30 inches (762 mm) minimum and 44 inches (1118 mm) maximum above the floor or ground surface....
- Allegion Falcon 2390 Series Recessed Exit Device
-
SIDEWALK
[DSA-AC] A surfaced pedestrian way contiguous to a street used by the public. (As differentiated from the definition of “Walk”.) Advisory Definition of SIDEWALK. ...
-
405.9.2 Curb or Barrier
curb or barrier shall be provided that prevents the passage of a 4 inch (100 mm) diameter sphere, where any portion of the sphere is within 4 inches (100 mm) of the finish floor or ground surface...
-
405.9.2 Curb or Barrier
curb or barrier shall be provided that prevents the passage of a 4 inch (100 mm) diameter sphere, where any portion of the sphere is within 4 inches (100 mm) of the finish floor or ground surface...
-
7.4.6 Tread Obstacles
Where the trail surface is paved or is elevated above the natural ground, tread obstacles shall not exceed ½ inch (13 mm) in height measured vertically to the highest point. ...
-
R406.2 Unobstructed Forward Reach
Where a forward reach is unobstructed, the high forward reach shall be 1220 mm (4.0 ft) maximum and the low forward reach shall be 380 mm (1.25 ft) minimum above the finish surface....
-
Check-Out Areas [8.3]
Check-Out Areas [8.3] Check-out counters at accessible lanes are held to a maximum surface height of 36 inches....
-
4.7.5 Openings
Openings in surface of the clear floor or ground spaces required by section 2.0 shall not allow passage of a sphere more than 1/2 inch (13 mm) in diameter....
-
WALK
[DSA-AC] An exterior prepared surface for pedestrian use, including pedestrian areas such as plazas and courts. (As differentiated from the definition of “Sidewalk”.)...
-
M303.2.6 Edge Protection
Where wheelchair spaces are provided on a platform raised more than 1 ½ inches (38 mm) in height, edge protection 2 inches (51 mm) high minimum measured from the surface of the platform...
-
WALK
[DSA-AC] An exterior prepared surface for pedestrian use, including pedestrian areas such as plazas and courts. (As differentiated from the definition of “Sidewalk”.)...
-
11B.707.7.1.2 Angle-mounted display screen
viewer 30 degrees to less than 60 degrees from vertical, the center line of the display screen and other display devices shall be no more than 44 inches (1118 mm) above the floor or ground surface...
-
Protruding Objects and Outdoor Recreation Access Routes
width area of an outdoor recreation access route, resting interval, or passing space and that are between 27 inches (685 millimeters) and 80 inches (2,030 millimeters) above the travel surface...
-
Obstructed High Reach: ADA Standard Section 308.3.2
Section 308.3.2 covers the current ADA Standards for obstructed high side reach.
-
11B-703.7.2.6 Toilet and bathing facilities geometric symbols
Geometric symbols at entrances to toilet and bathing rooms shall be mounted at 58 inches (1473 mm) minimum and 60 inches (1524 mm) maximum above the finish floor or ground surface measured...
-
11B-308.3.2 Obstructed high reach
Operable parts of fuel dispensers shall be permitted to be 54 inches (1372 mm) maximum measured from the surface of the vehicular way where fuel dispensers are installed on existing curbs...
-
11B-704.4.1 Height
When in use, the touch surface of TTY keypads shall be 34 inches (864 mm) minimum above the finish floor....